56
AURORA Installation instructions
|
jaga
HYDRAULIC CONNECTION
BENEFITS OF THE BUILT-IN HEIMEIER ECLIPSE VALVE
The Aurora is also equipped with a pre-assembled Heimeier Eclipse thermostatic valve for a right
downward connection of two ½” internal threads. The Heimeier Eclipse valve automatically controls
the maximum flow independently of the pressure difference, guaranteeing a perfectly balanced
system. The flow is directly set on the valve so that you don’t have to make any calculations for the
piping network to theoretically determine the pressure losses at the valves. The stepless setting
quickly and easily occurs by turning the numbered setting knob. Adjusting the valve and H-block, see
page 65.
Flow on the inside
Option: h-block
two pipes – single pipe
Option: h-block
two pipes – single pipe
Overview of the options: wall connection - euroconus
Flow on the outside
Overview of the options: floor connection - euroconus
type D
11 5.5
16 8.0
type D
11 5.5
16 8.0
Flow on the outside
Flow on the inside
Option: crossflow H-block
two pipes
Option: crossflow H-block
two pipes
5 3
D
3.7
2
5 3
D
3.7
5 3
D
2
5 3
D