JAE CT150-19D-MX80 Скачать руководство пользователя страница 10

DCF-S-0126-2A (06.04)

Japan Aviation Electronics Industry, Ltd.

Connector Div. Production Engineering Dept.

日本航空電子工業株式会社コネクタ事業部生産技術部

Number

番号

T700460

Page

10

10

JAE Connector Div. Proprietary.
Copyright

©

2020, Japan Aviation Electronics Industry, Ltd.

7.圧着条件

7.Crimping Condition

7-1.適用コンタクトと電線

7-1.Applicable wire & conatct

適用コンタクトと電線は下記表を参照ください。指
定外のケーブルを圧着される場合は、弊社まで
お問い合わせください。

Applicable wire is shown in below table. Using not
specified wire, please ask us whether the wire is
usable or not.

工具品名

Tool name

適用コンタクト

Applicable

contact

適用電線

Applicable Wire

被覆剥き長さ

Stripped length

電線種類

Wire type

被覆径

Insulation diameter

CT150-19D-MX80

MX80S08K4F1

(ソケットコンタクト)

Socket contact

FLRY-A0.35

7/

φ

0.25

FLRY-B0.35(12/

φ

0.19)

AESSX0.3

f(

19/

φ

0.16

φ

1.4mm

(φ

1.2

~φ

1.4mm

3.5

4mm

FLRY-A0.5

19/

φ

0.18

FLRY-B0.5(16/

φ

0.19)

φ

1.6mm

(φ

1.4

~φ

1.6mm

MX80P10K4F1

(ピンコンタクト)

Pin contact

FLRY-A0.35

7/

φ

0.25

FLRY-B0.35(12/φ0.19) 

φ

1.4mm

(φ

1.2

~φ

1.4mm

FLRY-A0.5

19/

φ

0.18

FLRY-B0.5(16/φ0.19) 

φ

1.6mm

(φ

1.4

~φ

1.6mm

7-2.圧着詳細

7-2.Crimping data

工具品名

Tool name

圧着部表示

Indication

on tool

1

電線サイズ

Wire size

被覆外径

Insulation

diameter

クリンプハイト値

Crimp height range

2

被覆巻高さ

Insulation

height

3

圧着強度

Crimp strength

4

CT150-19D-MX80

K4 0.35

0.35sq

φ

1.2

~φ

1.4

0.75

0.81 mm

1.6mm

50N

K4 0.5

0.5sq

φ

1.4

~φ

1.6

0.82

0.88 mm

1.8mm

75N

注意

CAUTION

1

CT150-19D-MX80

には圧着部が

2

ヶ所ありま

す。
コンタクトと電線サイズにより使い分けて下さ
い。

1

CT150-19D-MX80 has 2 crimping portion.
Please use properly according to contact and wire
size.

2

クリンプハイト値は、前記適用電線を入れて圧
着した場合のクリンプハイトです。
本クリンプハイトは、弊社の手動圧着工具にて
圧着した場合の設定値であり、他社製で圧着さ
れた場合は保証できません。

2

The crimp height value is the crimp height when
the above applicable wire is crimped together.
The crimp height range shown in the above table is
only applied in the product made by our hand
crimping tool and crimper. Don’t apply the number
in other maker’s product.

3

被覆巻き高さは参考値です。

3

Insulation height is reference value.

4

電線の導体部のみを圧着した時の引張り強度
が圧着強度です。
試作端子と試作工具のため、規格を満足しな
い場合があります。

4

The crimp strength is defined as the tensile
strength of the crimping, only when conductors of
the wire are crimped.
Because of prototype terminal and prototype tool, it
may not satisfy the standard.

本書に記載されている内容に関して、予告無く変更する場合があります。予めご了承ください。

There is no previous notice for the content that has been described in this book and
it is likely to change. Please acknowledge it beforehand

10/10

Содержание CT150-19D-MX80

Страница 1: ...neering Dept Prepared Checked Approved PL Approved K KOIDE N SAKAI C YANOSAKI JAE Connector Div Proprietary Copyright 2020 Japan Aviation Electronics Industry Ltd CRIMPING HAND TOOL CT150 19D MX80 OPE...

Страница 2: ...not followed WARNIN G A warning indicates an operation that could cause serious personal injury or fatal wound if precautions are not followed CAUTION A caution indicates an operation that could cause...

Страница 3: ...ur customer support department Please work while getting enough rest when you use this tool for a long time Injury might be caused for the body CAUTION Crimper and anvil can pinch the fingers Never pu...

Страница 4: ...Preparation of Crimping 5 4 4 Crimping 6 4 1 4 1 Handles opening 6 4 2 4 2 Contact setting 6 4 3 4 3 Wire setting 7 4 4 4 4 Crimping 7 4 5 4 5 Take out 8 5 5 Check of Crimped Contacts 8 6 6 Maintenanc...

Страница 5: ...refer to para 7 Check that each wire conductor is not damaged nor scratched Set any disarrayed conductors straight prior to the crimping operation Don t use one with cutoff and the crack in the wick...

Страница 6: ...SE Never put fingers into opening between the crimper and anvil 4 2 4 2 Contact setting From the back side push the locator and pull out the contact set part to the front With the locator pressed from...

Страница 7: ...applying it too much and note that it is likely to become defective crimping 4 4 4 4 Crimping While holding the wire and contact position as set close the handles gradually with being careful not to m...

Страница 8: ...ight is satisfied with crimp standard refer to para 7 2 2 2 Wire strands tip is extended from the wire barrel 3 3 Wire insulation does not intrude into the wire barrel 4 4 Wire strands do not protrude...

Страница 9: ...hand tool has a product life of 50 000 times Repair will not be performed except for repair of spring etc In addition inspection work such as presence of abnormality check of wear etc will be done 4...

Страница 10: ...l name Indication on tool 1 Wire size Insulation diameter Crimp height range 2 Insulation height 3 Crimp strength 4 CT150 19D MX80 K4 0 35 0 35sq 1 2 1 4 0 75 0 81 mm 1 6mm 50N K4 0 5 0 5sq 1 4 1 6 0...

Отзывы: