8
5-3 Function Setting
1) Turn on the power while pressing key
ZERO
.
Note: The following Steps (2) ~ (11) do
not require to operate in order.
2) Press numeric key
0
to shift backlight modes.
Options are On, OFF and OnOFF.
=Auto-on with items greater than 9d placed
on the pan.
= No backlight
= Backlight
3) Press numeric key
2
to set the level in which
the stable indication turns on (filtering) .The lower
the setting, the faster stabilization time.
Options are 1 and 2(level).
4
)
Press numeric key
3
to set the period of inactivity
before the scale automatically turns off. Options
are OFF(Non power-off)
、
5
、
10
、
30 and
60 (minutes).
5) Press numeric key
4
to set the range in which the
Zero indication turns on .Options are d0, d1, d2, d3, d4
and d5. (d= scale division)
6
)
Press numeric key
5
to select serial transmission
rates. Options are 9600, 4800 and 2400 .
7) Press numeric key
7
to set buzz sounds. Options
are Un
,
In
,
no
,
Lo and nbEEP.
=There will be a warning sound when the quantity of the articles exceeds the upper limit.
=There will be a warning sound when the quantity of the articles is between the upper and
lower l limit (including the upper and lower limits).
= There will be a warning sound when the material quantity exceeds the upper and lower
limits,
and the weight of the material is more than 20 divisions.