                                                                                                                              Vetek Weighing AB 

                                                                       

                      JCL                                                                                                         

8

 

 

 

ACAI 

Automatic  Counting  Accuracy  Improvement  (ACAI)  results  in  a  more  accurate  count  by 
increasing the reference weight without the need to count additional parts. A higher reference 
weight is important when there is a risk of inconsistent piece weights or if the reference weight 
is close to the minimum. ACAI uses an initial averaging unit weight to count additional pieces 
that are placed on the scale .after a few seconds, the scale gives a beep as the new higher 
reference  weight  is  used  to  recalculate  the  averaging  unit  weight.  The  process  can  be 
repeated as long as the additional weight  is less  than the previous reference  weight.  Once 
this limit is exceeded ACAI is turned off. 

 

 

                 →

 

 

5-2-4 Accumulation, Accumulation Display and Accumulation Clear 

1) Enter the indicated unit weight, press key 

UWS

 

 

and put first piece of load on the weighing pan   
(Or into a tared container). (Refer to 7-2-2)   

2) Press key

 

M+

, the first accumulation event                                             

is displayed momentarily before

 

Symbol ― ‖   

pointing at

 

“M+”. 

The display reverts to normal 

weighing mode in a second, remove the first piece 
  of load. 

 

 

 

 

3) Put the second piece of load on, then Press key 

M+

 to add the second accumulation event 

into memory. Repeat step 2-3 till accumulation actions are finished. 

Note: Maximum is 99 pieces.   

Accumulation Display 

Press key 

MR

 to displays the total accumulation data (weight, count and number of 

weighments) and the first 10 accumulation events in detail. 

Accumulation clear 

To clear the total accumulation data or the first 10 accumulation events, Press key 

MC/CK 

while the data is displayed. Symbol ― ‖ disappears when the total accumulation data is 

deleted. 

6. Calibration 

1) For best results, calibrate the scale at regular intervals. Temperature changes, geographic   
gravity  variations,  altitude  changes  and  abuse  are  few  reasons  why  a  scale  may  need 
recalibration. 

Содержание JCL

Страница 1: ...Vetek Weighing AB JCL 0 User Manual counting scale JCL ...

Страница 2: ...5 Operation 5 1 Basic Weighing 5 1 1 Weighing 5 1 2 Tare Preset Tare 5 1 3 Unit Switch Operation 5 2 Basic Counting 5 2 1 Upper Lower Quantity Limit Checking 5 2 2 Entering a Known Unit Weight 5 2 3 Sample Counting ACAI 5 2 4 Accumulation Accumulation Display and Accumulation Clear 6 6 6 7 7 7 8 6 Calibration 6 1 Single Point Calibration 6 2 Linear Calibration 9 9 7 Setting Mode 10 8 Serial Interf...

Страница 3: ...in water or other liquids Service should be performed by authorized personnel only 3 Before Using the Product 3 1 Unpacking and Checking Open the package and check the instrument for transport damage Immediately inform your dealer if you have complaints or if parts are missing The package should contain Scale body User manual Stainless steel and plastic weighing pans Wire power cord 3 2 Installing...

Страница 4: ... 8 Power socket 9 Transport protection screw 10 Plug buckle 4 1 Specifications General Features Specifications Model JCL 1 5K JCL 3K JCL 6K JCL 7 5K JCL 15K JCL 30K Capacity kg 1 5 3 6 7 5 15 30 Weighing units g lb kg lb Display 3 backlit LCD displays 6 5 6 Digits Pan size 294X228X13 5mm Scale dimensions 341X294X104mm Power supply AC 110V 220V AC 10 or rechargeable battery 6V 4A ...

Страница 5: ... Stainless steel weighing pan Weighing platter easy to disassemble with anti cockroach design Dust proof PVC cover Low battery and charging status indication Accumulation of weight and quantity max 99 pieces Single point and linear calibration available Auto shut off for power saving 4 2 Front Panel 4 2 1 Display 1 Low battery indication 2 Tare or Preset Tare indication 3 Center of Zero indication...

Страница 6: ...r recalculated 11 M Symbol points at M when scale is in accumulation mode 12 UW Under entering a known unit weight mode Symbol points at UW when entered unit weight is lower than 4 5 of scale division Unit weight is too small for ensuring accurate quantity calculations 13 SMPL Under the sample counting mode Symbol points at SMPL when calculated unit weight is lower than 4 5 of scale division or th...

Страница 7: ...alue entered via numeric keys 8 M key Adds the indicated weight or piece count value into Accumulation memory 9 SMPL key Short press enters the sampling mode 4 3 Power Supply Power supply Please verify the local AC power source and switch the two stage switch to the proper place before plugging into the power outlet Alternative power supply 1 AC 110V 220V AC 10 2 6V 4A internal rechargeable batter...

Страница 8: ...ting at NET 2 To clear tare with an empty pan Press down the key TARE or key ZERO Preset Tare 1 Under the unload condition Enter tare value using the numeric keys together with key then press key TARE The weight window displays the tare value 2 Put the load on the container the scale will automatically deduct the value of the container from the total value Note during the process of Tare or Preset...

Страница 9: ...to zero mode 5 2 2 Entering a Known Unit Weight 1 Under the weighing mode use the numeric keys together with key to input unit weight value and then press UWS 2 Put the article on the weighing pan the scale starts counting Note points at UW when entered unit weight is lower than 4 5 of scale division 5 2 3 Sample Counting ACAI 1 Place samples onto the weighing pan Or into a tared container and inp...

Страница 10: ...S and put first piece of load on the weighing pan Or into a tared container Refer to 7 2 2 2 Press key M the first accumulation event is displayed momentarily before Symbol pointing at M The display reverts to normal weighing mode in a second remove the first piece of load 3 Put the second piece of load on then Press key M to add the second accumulation event into memory Repeat step 2 3 till accum...

Страница 11: ...all the weights 7 Press key SMPL to save and then press key ZERO to return to the weighing mode 6 2 Linear Calibration 1 Press and hold key TARE while powering on the scale 2 Again press key TARE to enter zero point calibration mode with flashing on the weight screen 3 Wait till appears and flashes on weight window put weights of 1 3 of full load on e g 15k model 1 3 of full load is 5kg 4 Wait til...

Страница 12: ...e automatically turns off Options are OFF Non power off 5 10 30 and 60 minutes 5 Press numeric key 4 to set the range in which the zero indication turns on Options are d0 d1 d2 d3 d4 and d5 d scale division 6 Press numeric key 5 to set serial transmission rates Options are 9600 4800 and 2400 7 Press numeric key 7 to set buzz sounds Options are Un In no Lo and nbEEP There will be a warning sound wh...

Страница 13: ...the unit is turned on 9 Press numeric key 9 to shift print modes Options are Prt Pr Prt Co and Prt St If Prt Co is chosen as the print mode PC will be automatically selected as the external devices manual print continuous print Stable printing the weight of weighted articles should be more than 9 divisions Weighted articles should be removed and the scale goes back to zero before print out the nex...

Страница 14: ...ed the three functions can be enabled 8 1 RS 232 Connector 8 2 Single Option 1 RS 232 RTC Relay AH TDP ZEBRA TP SH EZ printer 2 RS 232 RTC Relay LED Light Tower Applicable to the quality control of the factory product quantity or weight and that of the total production line 3 RS 232 RTC Relay Computer 8 3 RS 232 Output Format Baud Rate 2400 4800 9600 Data Bit 8 Parity N None Stop Bit 1 Code ASCII ...

Страница 15: ... lb pcs Total 4pcs G GROSS N NET 9 Troubleshooting and Error Message Error message Problems Solutions Initial zero point exceeds 30 take 30 as reference basis 1 To check whether there are other alien articles on the scale pan remove those articles 2 LOAD CELL failure which requires to be changed or to contact our Service Higher or lower than A D resolution range 1 Check whether it is A D failure i...

Страница 16: ...he item exceeds the maximum tolerance The accumulated number of weighments total count or weight exceeds display range No more accumulation The quantity of weighed articles exceeds display range when the scale is under unit weight entering or sampling mode Low battery Recharge the battery The scale can be used while it is recharging ...

Страница 17: ...Vetek Weighing AB JCL 15 ...

Отзывы: