Prt-03

(printing in English)   

                      Prt-03

CK printing in Chinese

 

 

 

 

 

 

 

 

 

When the window of unit weight shows

,

 the printing format of accumulation display 

is as follows 
 
 
 
 
 
 
 
 
 
 
NOTE: 

The  printing  sample  could  be  of  different  kinds  of  formats. When  there  is  specific  demand 

about the format, conduct as follows 

1)  As for 

BRICH/GODEX/ZEBRA/GP 

printers, the factory designs the format as planned and 

email  to  the  user.  Add  the  format  into  the  previous  format  file  via  computer.  Then  it  is 

successful to add the new format and able to print the new format. 

2)  As for 

DMP

 

and

 

CK 

printers, it needs to change the scale design

 

 

Appendix 2

Exporting data to PC in the form of EXCEL 

Introduction: 

Connect the scale with PC and set the parameter of external device as “EXCEL” on the scale, 
then you could export the weighing data to PC in the form of EXCEL. With this function, you 
could  record/accumulate/average/data  statistical  analysis  the  testing  data,  which  we  could 
call it as 

scale-computer data management function

Note: pls enable “Use Serial Keys” function in the computer. 
 

Hardware connection and settings 

1.  Use transmitting serial wire or USB wire to connect scale and pc. 

2010-11-12 

13:14:15 

净重

:   

          0.500    kg 

单重

:   

          0.0500 kg

/

pcs 

总重

:   

          10 pcs 

2010-11-12 

13:14:15 

N.W.:   
          0.500    kg 

U.W.:   

          0.0500 kg

/

pcs 

Total:   

          10 pcs 

      2010.01.01 
        06:31:54 
(01)        1.000 kg 

20 pcs 

(02)        1.000 kg 

20 pcs 

(03)        1.000 kg 

20 pcs 

---------------------- 
(03)        3.000 kg 
                    60 pcs 

Содержание JCL-3K

Страница 1: ...e and Multi point Calibration 8 7 Operation 7 1 Weighing 9 7 2 Tare Preset Tare 9 7 3 Checking function 7 3 1 Upper Lower Weight Limit Checking 10 7 3 2 Upper Lower Quantity Limit Checking 11 7 4 Basi...

Страница 2: ...or other liquids Service should be performed by authorized personnel only 3 Before Using the Product 3 1 Unpacking and Checking Open the package and check the instrument for transport damage Immediat...

Страница 3: ...ic and moisture Tare Preset Tare auto zero tracking Automatic counting accuracy improvement ACAI for enhanced counting accuracy HI OK LO quantity checking function Stainless steel weighing pan Weighin...

Страница 4: ...tem is selected when setting buzz sounds See 5 Function Setting setting buzz sounds OK Lamp ON Indicating parameter item or is selected when setting buzz sounds LOW Lamp ON Indicating parameter item i...

Страница 5: ...ht Window Displays weight of object on weighing pan or accumulated weight value 4 2 2 Keyboard 1 0 9 numeric keys Enters specific values for tare unit weight and other data entries 2 key Decimal point...

Страница 6: ...n inputting the figures 4 3 Power Supply Power supply Please verify the local AC power source and switch the two stage switch to the proper place before plugging into the power outlet Alternative powe...

Страница 7: ...he pan when it is stable 3 SET02 auto off time setting Options are off 5min 10min 30min and 60min Off close auto off function 5 10 30 60 Auto off with less than 9d of gross weight when there is not an...

Страница 8: ...9 SET08 external equipment setting PC JMS Godex BIRCH ZEBRA DMP GP CK ET CX U KEY PC computer output JMS connect with weighing system GODEX Godex printer paper size 5cm 3cm BIRCH Birch printer paper s...

Страница 9: ...or TARE to shift the figures Press key M HI or PRINT LO to modify the value or via numeric keys Press key M SAVE to save and shift the windows 16 SET15 weight memory parameter on off On display the l...

Страница 10: ...tion procedure 5 Add another weight 500g to the current weight The window will show the total weights value Press TARE to complete Repeat this step to complete the calibrations of on3 on4 and on5 6 Pr...

Страница 11: ...ZERO ESC Method 2 Enter the tare value by pressing the numeric botton the screen will show the tare value 1 Then press TARE 2 Place the items into the container and the weight of container will be tar...

Страница 12: ...uld be more than or equal to 20e When changing the Hi Lo value the scale will activate the weighing checking function automatically If the Lo value is higher than Hi value then the Hi value will becom...

Страница 13: ...1 Entering a Known Unit Weight and Unit weight Memory 1 Under the weighing mode use the numeric keys together with key to input unit weight value and then press UWS 2 Put the items on the weighing pan...

Страница 14: ...higher reference weight is used to recalculate the averaging unit weight The process can be repeated as long as the additional weight is less than the previous reference weight Once this limit is exce...

Страница 15: ...on Accumulation clear To clear the total accumulation data or the first 10 accumulation events press key MR or TARE to shift the events and then press key M HI to clear Symbol disappears when the tota...

Страница 16: ...ng mode 7 7 The Control from PC to Scale Optional Step 1 Install the three in one board with RTC RS232 and RELAY Connect RS232 and choose the external equipment PC Step 2 Open the serial port to modif...

Страница 17: ...t ERR3 Exceed the A D resolution range 1 Replace A D 2 Replace the load cell or contact the maintenance department ERR4 EEPROM Chksum failure Re weld EEPROM or contact the maintenance department ERR5...

Страница 18: ...2012 02 20 13 14 15 N W 0 500 kg U W 0 0500 kg pcs Total 10pcs 2012 02 20 13 14 15 0 500 kg 2012 02 20 13 14 15 10 pcs 2012 02 20 13 14 15 10 pcs 2012 02 20 13 14 15 0 500 kg 1 000 kg ST GW 100 00 1 0...

Страница 19: ...ge the scale design Appendix 2 Exporting data to PC in the form of EXCEL Introduction Connect the scale with PC and set the parameter of external device as EXCEL on the scale then you could export the...

Страница 20: ...t Windows XP as a example 1 Press Start Run and enter access cpl OK 2 In the dialog box Accessibility Options enter General option choose Use Serial Keys and press Settings In the dialog box Settings...

Страница 21: ...II 20 Export weighing data to Excel 1 Open Excel 2 Press Print then Excel will show Date and Weighing data 3 Use Format Cells to beautify Excel...

Страница 22: ...to link computer system directly such as EXCEL Express System ERP system and so on This connector is compatible with windows2000 xp Vista win7 win8 Linux Android system and the weighing data will show...

Страница 23: ...II 22 2 ERP System...

Отзывы: