  A conveniently located gas shutoff valve, external to the appliance is required for complete 

shutdown. 

 

  Be sure all valves are in a closed position before connecting to gas supply. 

 

  Connect appliance to gas supply line.  Under no circumstances should the gas supply line 

be smaller than the inlet pipe on the appliance.  Use pipe compound on all pipe joints.  
Compound must be resistant to the action of liquefied petroleum gases. 

 

  Check all gas connections for leaks using a soap and water solution.  

DO NOT USE AN 

OPEN FLAME FOR CHECKING PURPOSES.

 

 
 
 
 
 
 
 
 
 

NOTE:

  Your appliance was tested, rated and adjusted at the factory before shipment and 

should be ready for use at the site without any major adjustments. 
 

LIGHTING AND RE-LIGHTING INSTRUCTIONS 
 

  Your appliance is equipped with constant burning pilots.  Turn valves off.  Wait 5 minutes.  

Light pilots.  Adjust pilots’ flames by using a screwdriver to turn pilot valve screw clockwise 
or counter-clockwise.  Turn burner valves on. If pilots go out, turn off valves and repeat 
above procedure. 

 

MAINTENANCE INSTRUCTIONS 
 

  Contact the factory, factory representative or a local service company to perform 

maintenance and repairs. 

 

  For daily cleaning, turn “ON” burner valves for 2 to 3 minutes and then turn “OFF.”  Use 

warm water and mild cleanser on top grates.   

 

  Once a month, clean all burners with water and steel brush ensuring that all burner ports are 

free of debris.  Clean pilots in same manner.  Once cleaned and dried, re-light pilots and 
check for blockage.  As frequently as necessary, remove grease tray, empty and clean with 
mild detergent. 

  WARNING:  A GAS REGULATOR MUST BE INSTALLED FOR 
THE SAFETY AND PROPER OPERATION OF THIS APPLIANCE 

This appliance and its individual shut off valve must be disconnected from the gas 
supply piping system during any pressure testing of that system at test pressures 
in excess of ½ psig (3.45 kPa).  The appliance must be isolated from the gas 
supply piping system by closing its individual manual shut off valve during any 
pressure testing of the gas supply piping system at test pressure equal to or less 
than ½ psig (3.5 kPa). 