OPERATION
Operating Instructions
Initial Instructions
Using a garden hose, fill the spa with water to the
water line indicator mark on the skimmer frame.
WARNING: Do not provide power to the spa unless it
is filled with water to the normal water level. Refer to
water line indicator mark on skimmer frame. When-
ever the power is ON, the system will activate even
though no controls are operated. When there is not
sufficient water in the unit with the spa’s motor/pump
actuated, the circulation pump and heater could be
irreparably damaged. Not heeding this caution will
nullify the warranty. In addition to damaging the unit,
operating the spa with insufficient water could cause
a fire.
6
At the house service panel, turn ON the circuit
breaker or switch that controls the electrical service to
your spa. Make sure there is no other appliance on that
circuit.
Your spa is provided with a Ground Fault Circuit
Interrupter (GFCI) on the cord end. At initial start-up and
before each use thereafter, with power on, push test
button on the GFCI. The reset button should pop out.
Push this button in to reset. If the interrupter fails to
operate in this manner, there is a ground current flowing
or a device malfunctioning, indicating the possibility of
electric shock.
Turn OFF power and do not use the spa until the
source of the problem has been identified and cor-
rected.
Control Panel
HIGH HEAT LIMIT
PUSH TO RESET
COLD
THERMOSTAT
HIGH LIMIT
RESET SWITCH
SELECTOR
SWITCH
TIMECLOCK
TIMED FILTRATION
AND HEAT POSITION
TIMED FILTRATION
AND AUTO HEAT
TEST
RESET
GFCI
HOT
TIMED FILTRATION
AND AUTO HEAT
TIMED FILTRATION
AND HEAT POSITION
Temperature Control
To increase the temperature, turn the thermostat
clockwise to the desired setting. To reduce the tempera-
ture, turn the knob counter clockwise.
Selector Switch
This switch selects the unit’s heating and filtering
functions.
Timed Filtration and Heat Position
In this position, the spa will heat and filter only when
the clock comes on.
Timed Filtration and Auto Heat Position
If the temperature falls below that set by the thermo-
stat, the low pump and heater will come on and run the
spa until the thermostat setting is reached. To increase
the temperature, turn the Temperature Control Knob
clockwise to the desired setting. To reduce the tempera-
ture, turn the knob counter clockwise. Filtration is
controlled by the time clock.
Filter Cycles & Setting Timer
The clock operates the spa’s filtration cycles.
To set the time of day: rotate the entire dial until the
clock indicates the correct time of day.
To set the filtration cycles: locate the tabs for the
time periods for filtration and push from the inside
towards the outside. Press one tab for each 15 minutes
of the filter period. The entire group of tabs between the
on-time and the off-time must be depressed. It is
suggested that the spa filter for at least 4 hours a day.
This time can be divided into 2 cycles 12 hours apart.
Over Heat Protection
In the event the spa should overheat, the spa will
shut down. If this situation occurs, turn off all power to
the spa and contact your dealer or service organization.
To reset the spa, press the High Limit switch. The time
of day may also have to be reset.