background image

 

 

 

 

 

 

Z-150/235 

Dimensions:       90x78x32 

                            92x82x32 

Capacity:            290g 

Empty Weight:   410 lbs 

Water Weight:    3728 lbs 

Voltage:              230vac 

Pumps:               Two 1hp Pumps 

Heater:               5.5kw     

 

 

 

 

Pump (Wetend Only) 

CC-1p 

Motor Only 

2500-200 

Pump/Motor Complete 

2500-250 

Heater 

2600-050 

Board 

2600-601 

Topside 

2500-152 

 

 

Pump (Wetend Only) 

CC-1p 

Motor Only 

2500-200 

Pump/Motor Complete 

2500-250 

Heater 

2000-684 

Board 

2600-005 

Topside 

2500-154 

Содержание Z Builder Series

Страница 1: ...Spas For the Following ELECTRONIC Spas Made 1995 2001 Dealer Premium Model Line sold through dealers Z Builder Series Line sold through big box stores does not include Z101 Published by Clear Creek Sp...

Страница 2: ...N THE SPA S MAIN POWER OFF UNLESS REQUIRED TO PERFORM A TEST WHEN YOU DO HAVE POWER ON BE CAREFUL AND USE PROPER ELECTRICAL PROTECTION AND PROCEDURES Although this booklet should be able to guide you...

Страница 3: ...pter Five Pressure Switch Flow Switch Chapter Six Sensors Chapter Seven Topside Control Chapter Eight Ozonators Chapter Nine Mood Lights Chapter Ten Plumbing Chapter Eleven Spa Jets Chapter Twelve Ste...

Страница 4: ...uzzi Whirlpool Bath was also the time the industry was switching to electronic controlled spas Therefore I experienced the changes that have occurred during this time and continue to work in the field...

Страница 5: ...ng so made spas available to many who could not afford to buy the dealer line of spas This manual focuses on both the Dealer line of Jacuzzi Whirlpool spas and the Z series SPA SHELL Jacuzzi s spa fin...

Страница 6: ...plastic sheet and screwed to the spa frame An attempt to economize cost panels were built of various woods and stained but this has been discontinued Most common now are synthetic plastic panels or s...

Страница 7: ...that hold the motor together Then the impellor which attaches to the motor shaft When the impellor rotates its what moves the water Between the impellor and the bracket is the seal The seal is a two p...

Страница 8: ...pump The J and K pump are a volume pump at low pressure What this means is that they are designed to move a large volume of water but not at high pressure It s easy to compare the Jacuzzi pump as a wi...

Страница 9: ...p cord from the control box Remove pump motor assembly Disassemble Pump wetend A Remove 4 bolts holding the front face of the pump volute to the pump housing B You will see the eye seal on the nose of...

Страница 10: ...e red high wire The bottom is the black low wire Extra Help If you strip the bolts that hold the pump face volute to the J light pump housing bracket you can easily buy a long bolt and nut locally and...

Страница 11: ...have TWO High Pressure pumps to drive the jets The circulation pump handles the heating and filtering Compare the 2 pump with the 1 Pump If they have an identical face they are both 1JPumps If the 2...

Страница 12: ...rab the motor shaft between the pump and motor with a pair of vice grips and hand turn the impellor loose If that doesn t work you will have to use a wrench on the impellor to separate This will likel...

Страница 13: ...suggestions found in later Chapters Circulation Pump On early Pinnacle you have either a smaller 110 130vac circulating pump or a larger 220 240vac circulation pump Replacement is easy for both Usual...

Страница 14: ...pump motor will come with a cord It easy to splice the wires together On the larger circ pump you will remove the cord connection from the back of the motor and install into the new...

Страница 15: ...better design it s a personal preference The two basic flow methods start the same way the water is pulled from the lower part of the spa called suction fittings and one or two assemblies with filter...

Страница 16: ...inserted into the heater assembly On the Pinnnacle Model the heater used is a similar model to the first production model but longer On the Z112 models they used a short horizontal heater on the top o...

Страница 17: ...ust be used Save the nuts because you normally must reuse them Disconnect heater assembly from plumbing ID the heater strap holding the heater in place Reach around to the back of the strap where the...

Страница 18: ...an comfortably reach down and loosen the 2 other bolts holding the heater in place Remove bolts or loosen to end Now the only thing holding the assembly in place are the OH sensor and the two wires co...

Страница 19: ...s on the upper strap holding the heater assembly I usually only loosen the lower 2 bolts to the end of their thread This will allow you to remove the heater assembly Reverse to install Tighten nuts sc...

Страница 20: ...when loosing tightening so you don t bend the heater posts Remove old heater Reverse above to install new heater On Vertical Heater For spas with a vertical heater on the left side of the control box...

Страница 21: ...opside motors and heaters Some will notify you when its time to replace the filter They are design both to make operation of the spa easier keep the water cleaner and filter the water on a regular bas...

Страница 22: ...hours These cycles usually default when you first power up the spa Then it filters 2 hours at that point and 12 hours later On some models you can set a jumper on the board to increase the cycle 5 hou...

Страница 23: ...control box They are helpful but it s better to replace the board systematically F106 7 and F108 9 These boards are fairly easy to replace if you are careful First turn off main power at the main brea...

Страница 24: ...main power b Remove control box cover c Unbolt the 2 bolts holding the copper straps to the board Save for reuse d Unplug phone type cord from board e Label incoming power line to which terminal they...

Страница 25: ...oosen the screws that hold the incoming cord The hardest thing about the replacing the board is its in a small space It has 1 2 screws holding the board to the box and 2 nylon posts Remove the screw s...

Страница 26: ...g the bottom of the seating area and applying air into those nozzles Electronic spas have an automatic blowout at least a couple of times a day The spa will turn on several times a day and run for a c...

Страница 27: ...ter element If sufficient pressure closes the microswitch the board turns the heater on Otherwise it does not Due to the low pressure of Jacuzzi pumps 2 speed pumps should use a 1lb pressure switch 2...

Страница 28: ...way I remove the board except for the wires connected directly to the board I swing the board out and to the left and protect the board Now any water that comes out of the pressure switch hole will no...

Страница 29: ...acuzzi s spas use pressure switches It wasn t until about 2000 did Jacuzzi introduce the flow switch on it s electronic spas specifically late editions of the Pinnacle the Triton and some Quantum Plus...

Страница 30: ...t is how is determines spa temp Some spas have their temperature sensor inserted into the actual spa Others in a housing inserted into the spa Jacuzzi s most common design is the sensor inserts into t...

Страница 31: ...ew sensor fast enough to minimize water The Over Heat sensor clips on the heater Again simply pull out Connection to the board The most common connection of the sensors to the board is a joint plug wh...

Страница 32: ...models it s a step process each time you press on the switch the board responds going to the next step On other models its simply an on off response Example Press the air blower button on the topside...

Страница 33: ...spas require a hot wired method your spa s control system should have a socket designed for an ozonator to plug in Once the ozonator is plugged in depending on the configuration of the spa the board...

Страница 34: ...of colors through red blue and green bulbs Some systems allow you to chose the color some follow a certain rotation and others allow you to start and stop at certain colors Many system that came with...

Страница 35: ...is care First you need clean both inside and outside of couplings and pipes that will come into contact Then prime Primer cleaner remove dirt and soften the plastic Again do both side of the pipe whe...

Страница 36: ...he older have the AMH jet with is a medium size jet with directional nozzle but you can adjust the flow This jet is commonly used in the footwell area Because you can t adjust the flow the water from...

Страница 37: ...o DC and lowers the voltage to 12 volts Jacuzzi used major brand car radios to add music and outdoor speakers Some stereos pick up noise when on AM but not FM I have found the common problem is the st...

Страница 38: ...er all possibilities Just make it a routine to turn off main power when doing any service There are only a handful of times you might have to do tests that require power to be on Special care must be...

Страница 39: ...TROUBLESHOOTING SECTIONS I Trips GFCI or GFI II Doesn t Heat III Motor hums IV Pump Leaks V Diagnosing by CLICKS VI Error Codes on the Topside...

Страница 40: ...top and below to loosen and remove the nut Do so You will then have a totally disconnected heater from the loop Turn ON power If the spa comes on and operates fine without tripping the gfci as it did...

Страница 41: ...er 110 130vac or 220 260vac depending on your spa and incoming power service To check remove the metal cover on the control box Turn on spa and let the motor come on and the heat light to come on soli...

Страница 42: ...end to fail one of two ways They no longer pass current through the element and therefore no longer heat The most common cause of this failure is water quality Over time water quality can cause the el...

Страница 43: ...balanced and not using too much or too little chemicals...

Страница 44: ...he possibilities most techs will opt to replace the motor rather than having it rebuilt A major reason is economics both for the tech and the homeowner If the customer pays the cost of removing rebuil...

Страница 45: ...gether If you have leak from there make sure the bolts or screws that hold the halves together are tight or not stripped The s of the pump must be tight together Rarely but possible are the o ring sea...

Страница 46: ...see the temperature and overheat sensor are within tolerance and close to identical It also checks the pressure switch to confirm it s open If everything is fine CLICK 2 The 1 pump comes on If the spa...

Страница 47: ...failure is one of the sensors See the ERROR codes section But let me mention the failures that can occur here in case the ERROR doesn t display either in Digital readout or on some ECHO spas the heate...

Страница 48: ...vac check for that On 2 pump 220vac systems the 1 and 2 pump are labeled On most spas you can just ID the 2 slots the pump wires use for the white and black lines and check the voltage for 220 260vac...

Страница 49: ...n t work What the board will do is catch your short When the water reaches temp and turns the 1 pump off it immediately looks at the switch to make sure it s now open your wire has made it constantly...

Страница 50: ...ignal This rarely happens but when it does you have to replace the board The CLICKS are not over After the pump and heater come on and don t touch any topside control you will hear another CLICK That...

Страница 51: ...he pressure switch you can try turning the wheel one full turn clockwise Otherwise replace the pressure switch Flashing FLO or FL with temperature and possibly COOL or FC This means the board has turn...

Страница 52: ...pa is in Economy Mode Unit will go up to 20 degrees below the temperature set It is NOT a more economical setting It is usually set when you are on vacation and will not be using the spa STAN Standard...

Страница 53: ...the PC board or Not enough water is moving over the element which is a flow problem many times due to dirty filters or Failed sensor Flashing More On then Off Meaning PC Board sees a sensor failure I...

Страница 54: ...c Models AERO PLUS and SELECT ALEXA and DELFINO CIRRUS LEXUS PLUS LC and SELECT LASER PLUS and SELECT PALIO PINNACLE QUANTUM PLUS SANTINA SOLARIS TIRAGE TRITON Z 100 Z 110 Z 112 Z 120 Z 130 Z 135 Z 14...

Страница 55: ...elect Accessory Air Blower on Earlier Production None on Select Series Heater 5 5kw Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255 or CC F570HD Heater 2600 050...

Страница 56: ...Water Weight 1965 lbs Voltage 110vac Pumps ONE 2hp Pump Accessory None Heater 1 5kw Part Part Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255 or CC F570HD Heater...

Страница 57: ...1hp Pumps Accessory Air Blower Heater 5 5kw Some Models 3hp 2 Pump On those it uses a CC 3jp wetend 2500 203 motor or 2500 251 pump motor complete Part Part Pump Wetend Only CC 1jp Motor Only 2500 200...

Страница 58: ...ight 771 lbs Voltage 220vac Pumps Two Pump motor either 2 X 1hp OR 1 1hp and 1 3hp Accessory Air Blower Optional Heater 5 5kw Lexus Continues next page Part Part Pump Wetend Only CC 1jp Motor Only 250...

Страница 59: ...or 2500 251 pump motor complete Part Part Pump Wetend Only CC 1jp Motor Only 2500 200 Pump Motor Complete 2500 250 Heater 2600 050 Board 2600 016 Topside 2500 151 Part Part Pump Wetend Only CC 1jp Mot...

Страница 60: ...ght 409 lbs Water Weight 2558 lbs Voltage 115vac Pumps One 2hp 2 Speed Pump Heater 1 5 11kw Part Part Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255 or CC F570H...

Страница 61: ...lation Pump 2 High Pressure Single Speed Pumps Accessory Air Blower Optional AM FM Radio Heater 5 5kw Low Flow Part Part Circ Pump If Small Pump 110v Tiny Might If Large Pump 2500 259 High Volume 1 Sp...

Страница 62: ...ccessory Air Blower Heater 5 5kw Low Flow Part Part Pump Wetend Only CC 1jp and CC 3jp Motor Only 2500 200 and 2500 203 Pump Motor Complete 2500 250 and 2500 251 Small Circulation Pump if your spa has...

Страница 63: ...562 lbs Water Weight 4771 lbs Voltage 230vac Pumps Two Single Speed 1hp some models replaced one 1hp with a 3hp pump Heater 5 5kw Part Part Pump Wetend Only CC 1jp Motor Only 2500 200 Pump Motor Comp...

Страница 64: ...78x72x32 Capacity 249 g Water Weight 4281 lbs Voltage 230vac Pumps 2 x 1hp Heater 5 5kw Part Part Pump Wetend Only CC 1jp Motor Only 2500 200 Pump Motor Complete 2500 250 Heater 2600 050 Board 2600 01...

Страница 65: ...p and 1 3hp Pumps or 1 Circulation and 2 High Pressure Pumps Accessory Air Blower Heater 5 5kw Part Part Pump Wetend Only CC 1jp and CC 3jp Motor Only 2500 200 and 2500 203 Pump Motor Complete 2500 25...

Страница 66: ...bs Voltage 230vac Pumps 1 Circulation Pump 2 Single Speed Pumps Accessory Air Blower Optional AM FM Radio Heater 5 5kw Part Part Circulation Pump 6500 035 Pump Motor Complete 6500 763 Heater 6500 301...

Страница 67: ...s Water Weight 2365 lbs Voltage 110 220vac Pumps One 2 Speed 110v Pump Accessory None Heater 1 5 5 5kw Part Part Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255...

Страница 68: ...Heater 1 5 5 5kw Pump Wetend Only CC 2jp Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255 or CC F570HD Pump Motor Complete 2500...

Страница 69: ...s Water Weight 3129 lbs Voltage 110 220 vac Pumps One 110vac 2hp Pump Accessory None Heater 1 5 5 5kw Part Part Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255 o...

Страница 70: ...Weight 430 lbs Water Weight 3641 lbs Voltage 110 220vac Pumps One 110vac 2hp Pump Accessory None Part Part Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255 or CC...

Страница 71: ...apacity 325 g Empty Weight 587 lbs Voltage 230vac Pumps TWO 1hp Pumps Accessory None Heater 5 5kw Part Part Pump Wetend Only CC 1p Motor Only 2500 200 Pump Motor Complete 2500 250 Heater 2600 050 Boar...

Страница 72: ...Pump Heater 1 5 5 5kw Part Part Pump Wetend Only CC 2jp Motor Only 2500 204 or CC C180 HD Pump Motor Complete 2500 255 or CC F570HD Heater 2600 050 Board 2600 015 Topside 2500 152 Pump Wetend Only CC...

Страница 73: ...Voltage 220vac Pumps Two 1hp Pumps Heater 5 5kw Part Part Pump Wetend Only CC 1p Motor Only 2500 200 Pump Motor Complete 2500 250 Heater 2600 050 Board 2600 601 Topside 2500 152 Pump Wetend Only CC 1p...

Страница 74: ...lbs Voltage 230vac Pumps Two 1hp Pumps Heater 5 5kw Pump Wetend Only CC 1p Motor Only 2500 200 Pump Motor Complete 2500 250 Heater 2600 050 Board 2600 601 Topside 2500 152 Pump Wetend Only CC 1p Motor...

Страница 75: ...ght 619 lbs Water Weight 3878 lbs Voltage 220vac Pumps Two 1hp and 3hp Accessory None Heater 5 5kw Pump Wetend Only CC 1h CC 3hp Motor Only 2500 200 or 2500 203 Pump Motor Complete 2500 250 or 2500 25...

Страница 76: ......