Jacuzzi Tirage Plus 8900000 Скачать руководство пользователя страница 6

MINIMUM SERVICE ACCESS

3

Important: 

 Read complete instructions before beginning installation.

Positioning Your Spa

Because your  spa is  portable, you can locate it just about anywhere you wish--on a deck, patio, or even indoors.

Just be sure to position it above ground in an area with good drainage and on a level, continuous surface which can
support the weight of the spa when filled with water and people; this weight is approximately 4874 lbs. (86 lbs. per
square foot).  You must also provide access to the spa's equipment for service and general maintenance.

Electrical Requirements

Your Spa, as it comes from the factory, requires a 230

VAC 60 AMP 4-wire grounded type electrical service
having copper connectors and must be in a  separate
circuit having no other appliance connected  in that
circuit.  If you do not have this kind of circuit, a qualified
electrician should be called in to install the necessary
wiring.  Inadequately sized wiring may cause a voltage
drop which might cause the unit to malfunction and bring
about permanent damage to the spa's electrical system.
We recommend that the wire be sized for a 3% voltage

INSTALLATION

drop. (See NEC.) Each "leg" of the incoming power to
neutral must be 105 VAC minimum at the spa when all
the spa equipment is running.   The circuit must also
have a ground wire in order to take advantage of the
designed-in safety features of the spa. A bond wire must
also be used.  Bond according to procedure described
on the next page.

Caution:

 Without proper grounding and bonding, a

system malfunction may cause fatal shock.

32"

87"

EQUIPMENT DOOR

Содержание Tirage Plus 8900000

Страница 1: ...WHIRLPOOL BATH R THE TIRAGE PLUS PORTABLE WHIRLPOOL SP A OWNER S MANUAL...

Страница 2: ...m See Installation Instructions to drain water away from electrical components Do not turn on power to the spa unless it is filled with water to the normal water level which is to the water level indi...

Страница 3: ...___________________________________ 10 Silent Air Induction ____________________________________________________ 10 Filtration ____________________________________________________________ 10 Maintenan...

Страница 4: ...t and is equipped with a ground fault circuit interrupter GFCI An optional gas heater is available as an alternate heating source and can be installed remotely The Tirage Plud is available in a wide r...

Страница 5: ...p the spa over onto its bottom with the block supporting the spa 6 Remove the bolts attaching pallet to spa See Illustration D 7 Remove the pallet and carefully lower the spa to a horizontal position...

Страница 6: ...ng copper connectors and must be in a separate circuit having no other appliance connected in that circuit If you do not have this kind of circuit a qualified electrician should be called in to instal...

Страница 7: ...commend that you provide a concrete pad for it to rest on To do this construct forms for a 8 x 8 x 4 approx thick level pad Install a 10 gauge wire mesh 6 x 6 steel reinforced grid Attach a 8 solid co...

Страница 8: ...Fill the spa with water to its normal operating level which is to the water level indicator mark on the skimmer filter frame Turn on circuit breakers at the main electrical panel Select JETS on the S...

Страница 9: ...FETY SWITCH High temperatures above the thermostat range will cause the high temperature safety switch to trip and the system to turn off See operating instructions When water temperature is less than...

Страница 10: ...ained at the mini mum temperature approx 50 degrees during the time period set on the timer Setting the Timer The built in 7 day timer is located in the System Control Module The tooth like tabs that...

Страница 11: ...For best performance and increased equipment life pause a second or two between push button selections Not pausing may cause the switch to malfunction ACCESSORY The ACCESSORY switch controls these fun...

Страница 12: ...when the heater has just turned off the indicator lamp on the control panel will turn off at this time 9 OPERATION TEMP CONTROL Turn on the heater by selecting the HTR FLTR mode with the SYSTEM switc...

Страница 13: ...ever thewatertemperaturereachesthedesiredtemperature the pump will turn off For continuous filtration select FILTER on the SYS TEM switch In this mode the filter pump will run until it is manually dea...

Страница 14: ...ty and water chemistry in your spa is extremely important and should be a regular part of your spa maintenance program as a neglected spa can be a breeding place for dangerous bacteria The water quali...

Страница 15: ...m could be corro sive and damage your spa system Superchlorination also referred to as shock treatment The addition of an above normal level of disinfectant to kill any bacteria or algae that might ha...

Страница 16: ...ols to OFF Then turn off circuit breakers at the main electrical panel Pass a garden hose through a hole in the pan and connect it to the hose bibb in the suction plumbing Turn the handle and drain th...

Страница 17: ...ow the procedure outlined for winterizing your spa in a warm climate See Winterizing Note We do not recommend using this procedure if you are absent during the summer when algae build up is most likel...

Страница 18: ...ace of acrylic is tough and durable and contains concentrated color This is sup ported by a substantial thickness of fiberglass rein forced polyester resin A catalyst causes a chemical reaction during...

Страница 19: ...ndicator mark on skimmer filter frame C Clean strainers or skimmer baskets D Clean or replace E Open jet 1 Control Switches do not re spond A Actuated too rapidly B No power to the unit C High Tempera...

Страница 20: ...ripped E GFCI tripped F Improper or defective wiring G High temperature safety switch tripped A Turn on power at service panel B Select FILTER HTR FLTR or JETS mode C Reset circuit breaker D Reset cir...

Страница 21: ...reset if problem persists see Note B C D Consult electrician to correct wiring to unit E Reset button on heater after water has cooled see Note if switch continues to trip 12 Air Blower does not opera...

Страница 22: ...cal plumbing codes may require the use of an anti siphon valve for such a connection Do not inter connect water supply with recirculating system of the spa To make the connections necessary to use the...

Страница 23: ...product Jacuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE USE INSTALL...

Отзывы: