background image

16

PROBABLE CAUSE

REMEDY

PROBLEM

3. Heater not functioning but

HEATER light on.

A. Relay malfunction.
B. Element malfunction.
C. Heater plug loose.

A. *
B. *
C. Check Heater Plug connection

4. Water not clean.

A. Clogged or blocked suction

strainer or skimmer basket.

B. Filter clogged (dirty).
C. Poor water chemistry.
D. Insufficient filtering time.
E. Improper maintenance.
F. High content of solids in water.
G. Filter motor plug not connected to

System Control Module.

A. Clean strainer/skimmer basket

B. Clean or replace.
C. See “Chemistry” section.
D. Run filter.
E. See Maintenance section.
F. Use clarifier or drain and refill spa.
G. Check Filter Motor connection on

System Control Module.

5. Abnormal water usage.

A. Leak in suction line, discharge line,

or connections.

B. Excessive evaporation and/or

splashing.

A. Repair leak.

B. Use rigid spa cover; lower thermostat

setting.

6. Low water flow from jets.

A. Normal operation in FILTER or

HTR/FLTR or AIR mode.

B. Low water level.

C. Clogged or blocked suction strainer

or skimmer basket.

D. Dirty filter.
E. Adjustable jet partially closed.

A. Select JETS mode for maximum flow.

B. Fill to water level indicator mark on

skimmer/filter frame.

C. Clean strainers or skimmer baskets.

D. Clean or replace.
E. Open jet.

1 . Control Switches do not re-

spond.

A. Actuated too rapidly

B. No power to the unit.
C. High Temperature Safety Switch is

tripped

A. Wait 60 seconds; system will be

restored automatically.

B. Turn on circuit breakers.
C. Reset button on heater after water has

cooled.  See *Note if switch continues
to trip.

2. Heater not functioning.

A. Heater mode not selected.
B. No power to heater.

C. Thermostat set lower than water

temperature.

D. High temperature safety switch

tripped.

E. Abnormally low water flow.
F. Heater relay not operating.
G. Heater element failure.
H. Flow switch not operating.

A. Select HTR/FLTR mode.
B. Check house circuit breakerand GFCI.
C. Turn to desired temperature.

D. Reset button on heater after water has

cooled; see *Note if switch continues
to trip.

E. *
F. *
G. *
H. Check flow switch and plug-in connec-

tion on System Control Module

CAUTION:

 This equipment requires qualified service personnel for proper repair.  Contact your Jacuzzi Whirlpool

Bath dealer or Authorized Service Agent for service.

TROUBLESHOOTING GUIDE

*Note:

The skills and tools necessary for the safe repair of this spa require the services of qualified

service personnel.  Contact your Jacuzzi Whirlpool Bath Authorized Service Agent or Dealer.

Содержание Tirage Plus 8900000

Страница 1: ...WHIRLPOOL BATH R THE TIRAGE PLUS PORTABLE WHIRLPOOL SP A OWNER S MANUAL...

Страница 2: ...m See Installation Instructions to drain water away from electrical components Do not turn on power to the spa unless it is filled with water to the normal water level which is to the water level indi...

Страница 3: ...___________________________________ 10 Silent Air Induction ____________________________________________________ 10 Filtration ____________________________________________________________ 10 Maintenan...

Страница 4: ...t and is equipped with a ground fault circuit interrupter GFCI An optional gas heater is available as an alternate heating source and can be installed remotely The Tirage Plud is available in a wide r...

Страница 5: ...p the spa over onto its bottom with the block supporting the spa 6 Remove the bolts attaching pallet to spa See Illustration D 7 Remove the pallet and carefully lower the spa to a horizontal position...

Страница 6: ...ng copper connectors and must be in a separate circuit having no other appliance connected in that circuit If you do not have this kind of circuit a qualified electrician should be called in to instal...

Страница 7: ...commend that you provide a concrete pad for it to rest on To do this construct forms for a 8 x 8 x 4 approx thick level pad Install a 10 gauge wire mesh 6 x 6 steel reinforced grid Attach a 8 solid co...

Страница 8: ...Fill the spa with water to its normal operating level which is to the water level indicator mark on the skimmer filter frame Turn on circuit breakers at the main electrical panel Select JETS on the S...

Страница 9: ...FETY SWITCH High temperatures above the thermostat range will cause the high temperature safety switch to trip and the system to turn off See operating instructions When water temperature is less than...

Страница 10: ...ained at the mini mum temperature approx 50 degrees during the time period set on the timer Setting the Timer The built in 7 day timer is located in the System Control Module The tooth like tabs that...

Страница 11: ...For best performance and increased equipment life pause a second or two between push button selections Not pausing may cause the switch to malfunction ACCESSORY The ACCESSORY switch controls these fun...

Страница 12: ...when the heater has just turned off the indicator lamp on the control panel will turn off at this time 9 OPERATION TEMP CONTROL Turn on the heater by selecting the HTR FLTR mode with the SYSTEM switc...

Страница 13: ...ever thewatertemperaturereachesthedesiredtemperature the pump will turn off For continuous filtration select FILTER on the SYS TEM switch In this mode the filter pump will run until it is manually dea...

Страница 14: ...ty and water chemistry in your spa is extremely important and should be a regular part of your spa maintenance program as a neglected spa can be a breeding place for dangerous bacteria The water quali...

Страница 15: ...m could be corro sive and damage your spa system Superchlorination also referred to as shock treatment The addition of an above normal level of disinfectant to kill any bacteria or algae that might ha...

Страница 16: ...ols to OFF Then turn off circuit breakers at the main electrical panel Pass a garden hose through a hole in the pan and connect it to the hose bibb in the suction plumbing Turn the handle and drain th...

Страница 17: ...ow the procedure outlined for winterizing your spa in a warm climate See Winterizing Note We do not recommend using this procedure if you are absent during the summer when algae build up is most likel...

Страница 18: ...ace of acrylic is tough and durable and contains concentrated color This is sup ported by a substantial thickness of fiberglass rein forced polyester resin A catalyst causes a chemical reaction during...

Страница 19: ...ndicator mark on skimmer filter frame C Clean strainers or skimmer baskets D Clean or replace E Open jet 1 Control Switches do not re spond A Actuated too rapidly B No power to the unit C High Tempera...

Страница 20: ...ripped E GFCI tripped F Improper or defective wiring G High temperature safety switch tripped A Turn on power at service panel B Select FILTER HTR FLTR or JETS mode C Reset circuit breaker D Reset cir...

Страница 21: ...reset if problem persists see Note B C D Consult electrician to correct wiring to unit E Reset button on heater after water has cooled see Note if switch continues to trip 12 Air Blower does not opera...

Страница 22: ...cal plumbing codes may require the use of an anti siphon valve for such a connection Do not inter connect water supply with recirculating system of the spa To make the connections necessary to use the...

Страница 23: ...product Jacuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE USE INSTALL...

Отзывы: