It is the responsibility of the installer/owner to ascertain
compliance with specific local regulations prior to installa-
tion. Jacuzzi Europe S.p.A. gives no guarantee in this respect
and declines all responsibility regarding the compliance of
the installation performed.
Technical Features
The Santorini Pro spa (
0
1;
0
2) has a capacity of about 1250
litres. Its power supply is single-phase (220/240 V), and all its
electromechanical organs and pipes are contained within its pe-
rimeter. It is equipped with two 2-Hp pumps and one recirculat-
ing pump.
The skimmer contains 2 filtering cartridges (filtering surface: 9.3
m2) which guarantee optimal water filtration.
Maximum absorption of the system
•
VERSION
WITH
HEATER
Power supply
(single-phase)
Hydro total
consu
fil heater
Blower
(Pro Sound)
Audio System
(Pro Sound)
Spa-Pak
(optional)
Volt
220-240 ~
50
23 (k)
5,15 (j)
0,6 (j)
0,25 (j)
2,5
(k)
Hertz Ampere
kW
kW
kW
Ampere
0,5 (j)
kW
•
VERSION
WITH
EXCHANGER
Power supply
(single-phase)
Hydro total
consumption
+ filtering
Blower
(Pro Sound)
Audio System
(Pro Sound)
Spa-Pak
(optional)
Volt
220-240 ~
50
8,8
(k)
1,95 (j)
0,6 (j)
0,25 (j)
2,5
(k)
Hertz Ampere
kW
kW
kW
Ampere
0,5 (j)
kW
(k): at 230 V (single phase)
- (j): absorbed power
The electrical system that powers the spa must absolutely be
sized for maximum consumption
(as shown in the table).
If suffi-
cient electrical energy is not available, an electronic energy con-
sumption limiter can be activated.
- alternative consumption: 3.6 kW
(when 1 hydromassage pump
is run, the electric heater goes off).
Heat exchanger (optional)
- MAX primary circuit temperature ........................................... 50 °C
- Connections .......................................................................................3/4”
- Primary circuit flow rate .......................................................38 l/min
- Primary pressure drop ...................................................0,271 m H
2
O
Weights
Net weight
average volume
of use
water volume
MAX
Total max. weight
kg
litres
litres
kg
~ 300
~ 1250
~ 1800
~ 2100
area
involved
support
area
average load
on concerned area
concentrated load
on support area
m
2
m
2
kg/ m
2
kg/ m
2
~ 4,47
~ 4,38
~ 470
~ 479
User safety
n
If installed by qualified personnel in compliance with the in-
structions in the enclosed installation manual, the system does
not present any risks for the user. However, safety is also contin-
gent upon appropriate use, according to the provisions in the
respective manual, while the user must delegate the operations
described in the installation manual to qualified personnel.
n
It is important to make sure that personnel tasked to install
or manage the system are qualified as per legal requirements in
effect in the country where installation is carried out.
Arrangement for installation
n
Models equipped with a Performance filtering group
The filtering assembly (spa-pak) can be located anywhere, but
not more than 4 m from the mini-pool. If installation is outdoors
(in very cold areas), it is recommended to provide valves that al-
low for complete drainage of the pipes that connect the spa to
the spa-pak.
If necessary, the spa-pak can be installed on a lowered surface
(with respect to the spa) with a maximum height difference of
1m. Greater height differences may reduce the flow rate of the
filtering pump.
The spa-pak must be installed so that it is cannot be accessed by
individuals without using keys, and protected from water and
inclement weather (an adequate ventilation must be provided).
n
You can use a garden hose to fill the spa.
If the spa is connected, for periodic filling, to the
mains system that supplies drinking water, this con-
nection must be carried out in compliance with the
EN1717 norm, using “AA”, “AB” or “AD” anti-pollution
protection procedures. For further information, we
recommend you contact your water supply company
and/or your plumber.
n
The customer must make provisions for a ground drainage
point of suitable dimensions and that can be inspected for any
cleaning that may be required.
n
Models equipped with a Performance filtering group: con-
nection must also be provided to the drain for periodic backwash
and possible emptying of the sand filter installed on the spa-pak,
as well as electrical and plumbing connection between the spa-pak
and the MaxiJacuzzi® (see the corresponding installation manual).
ATTENTION: Before preparing the ground drainage
point, consult the local authority for the regulations
that control the drainage of chemically treated water.
n
(
0
3, det. B) Especially when installed inside, it is advisable
to connect the connection on the base to the main drain pit. As
there is a large amount of water in the spa, this is a useful precau-
tion if water accidentally escapes and collects inside the base.
Содержание Santorini Pro
Страница 2: ......
Страница 3: ...n Italiano 12 n English 15 n Fran ais 18 n Deutsch 21 n Espa ol 24 n 27 Santorini pro Index...
Страница 5: ...5 2 0...
Страница 6: ...6 3 0 A B 8 cm 8 cm 12 cm 90 cm 2 1 2 A B A B A B A B 1...
Страница 7: ...7 20 mm 1 2 2 3 A B 3 4 1 3 3 4 NO OK 2 T P P T...
Страница 8: ...8 4 0 C 23 cm 25 cm 96 cm 17 cm C 3 4 IN OUT...
Страница 10: ...10 A A A A A 12 cm 8 0 7 0...
Страница 11: ...11 20 mm 2 2 4 4 5 5 1 3 3 9 0 10 0...
Страница 30: ...30 30 5 n spa n spa JacuzziEurope...
Страница 31: ...31 31...