Limitation of electricity consumption
If you do not have enough electricity and decide to turn the con-
sumption limiter on, you must configure the system software as in-
dicated (refer to the wiring diagrams to identify the type of electrical
box on board the hot tub).
X
Make sure the spa is disconnected from the power supply line.
X
Remove the cover of the electrical box and set the switch
("dip-switch") n °
1
to the
OFF
position.
1
2
3
4
5
6
7
8
ON
Q
PROFILE "TOP"
X
In the
OFF
position, the electric heater switches off when a
whirlpool pump is activated.
Q
PROFILE "BASE" (DSP)
X
In the
OFF
position, the electric heater switches off when the
whirlpool pump is activated in high speed.
NOTES
- When dipswitch 1 is set to ON, the maximum electrical consump-
tion is selected.
Check of operation
First start-up
X
Check that the filter cartridge is present in its container and
that the various components are properly installed
(see the chap-
ter on maintenance of the filter cartridge).
A
A
X
Check that the drain valve (V) on the base
(and the ball valve
V1, if installed
) are closed
.
V1
V
X
Check that all the hydromassage intakes are open.
Содержание Profile
Страница 2: ...2...
Страница 9: ...9 1 2 3 1...
Страница 11: ...11 A1 A2 B2 B1 A1 A2 B1 B2 3 2 5 mm 2 9x19 mm 1 2 3 4...
Страница 82: ...82 Ru Jacuzzi Europe S p A EN1717 AA AB AD 0 C 0 C 12 Jacuzzi 1 30 A H 05 VV F III IEC60335 1 600 a 6 35 a 0 35...
Страница 93: ...93 ON smart winter...
Страница 94: ...94 B2 dip switch 2 LL L1 L2...
Страница 95: ...95 Jacuzzi Jacuzzi Europe S p A...