Page 2
7. To gain access to the spa’s power terminal block, remove the
screws securing the cabinet panel on the side of the spa under the
controls. Then remove the four control box door screws and door
(Figure-B).
8. Select the power supply inlet you want to use (Figure-A). Feed
power cable to control box, then install it through the large opening
provided in the bottom side of the box.
9. Connect wires, color to color, on terminal blocks TB and TB3
(Figure C-F, page 3). TIGHTEN SECURELY! All wires must be
hooked up securely or damage could result.
0. Install control box door and screws and reinstall the cabinet side
panels.
Figure-B - Control Box
. Terminal Block
2. Bonding Lug
3. Grounding Terminal
TB
3
2
9
0
4
3
7
2
2
Figure-A
Equipment Area
. Control Box
2. Power Supply Inlet(s)
3. 2-Speed Jets Pump #
4. Heater
5. Spa Drain Valve
6. Pump Drain Plug(s)
7. -Speed Jets Pump #2
8. Circulation Pump
9. optional CD ozonator (Purchased Separately)
0. ozone Injector
Flow
Note: Pump Locations Vary by Model
Circulation Pump
Behind Load Box
8
5
6
6
Содержание Premium J-315