WARNING

 – 

Risk of Electric Shock.

  All electrical wiring MUST be in conformance with applicable local 

codes, regulations, and the National Electric Code (NEC).  Hazardous voltage can shock, burn, and cause death or serious 
property damage.  To reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply.  
Provide a properly located electrical receptacle.    Before working on pump or motor, turn off power supply to the pump. 

 

WARNING

 – To reduce the risk of electric shock replace damaged wiring immediately.  Locate conduit to 

prevent abuse from lawn mowers, hedge trimmers and other equipment. 

 

WARNING

 – 

Risk of Electric Shock.

  In accordance with the National Electric Code (NEC), connect only 

to a branch circuit protected by a ground-fault circuit-interrupter (GFCI).  Contact a qualified electrician if you cannot 
verify that the circuit is protected by a GFCI.  The unit must be connected only to a supply circuit that is protected by a 
ground-fault circuit-interrupter (GFCI).  Such a GFCI should be provided by the installer and should be tested on a routine 
basis.  To test the GFCI, push the test circuit button.  The GFCI should interrupt power.  Push the reset button.  Power 
should be restored.  If the GFCI fails to operate in this manner, the GFCI is defective.  If the GFCI interrupts power to the 
pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock.  Do 
not use this pump.  Disconnect the pump and have the problem corrected by a qualified service representative before 
using. 

 

WARNING

 – Failure to bond pump to pool structure will increase risk for electrocution and could result in 

injury or death.  To reduce the risk of electric shock, see installation instructions and consult a professional electrician on 
how to bond pump.  Also, contact a licensed electrician for information on local electrical codes for bonding requirements. 

Notes to electrician:

  Use a solid copper conductor, size 8 or larger.  Run a continuous wire from external bonding lug 

to reinforcing rod or mesh.  Connect a No. 8 AWG (8.4 mm

2

) [No. 6 AWG (13.3 mm

2

) for Canada] solid copper bonding 

wire to the pressure wire connector provided on the pump housing and to all metal parts of swimming pool, spa, or hot 
tub, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of 
swimming pool, spa, or hot tub.  IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, 
grounding, bonding and other general wiring procedures. 

 

WARNING

 – 

Suction Entrapment Hazard.  

Suction in suction outlets and/or suction outlet covers, which 

are damaged, broken, cracked, missing, or unsecured cause severe injury and/or death due to the following entrapment 
hazards (symbols complements of APSP): 

Hair Entrapment

 - Hair can become entangled in suction outlet cover. 

Limb Entrapment

 - A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, 

broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. 

Body Suction Entrapment

 - A differential pressure applied to a large portion of the body or limbs can result in an 

entrapment.  

Evisceration/ Disembowelment

 - A negative pressure applied directly to the intestines through an unprotected suction 

outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in 
evisceration/disembowelment. 

Mechanical Entrapment

 - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be 

caught in an opening of a suction outlet cover resulting in mechanical entrapment. 

 

 

 

 

Содержание JVS185S

Страница 1: ...ge 1 of 32 IS3206VSP3J Rev A JVS185S JVS270S Owner s Manual Note To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely SAVE THIS INSTRUCTION MANU...

Страница 2: ...Page 2 of 32 IS3206VSP3J Rev A...

Страница 3: ...d Digital Control Interface Wiring Optional 16 5 5 Remote Stop Switch Wiring Optional 17 6 Startup Operation 17 6 1 Prior to Start Up 17 6 2 Starting Priming the Pump 18 6 3 User Interface Summary 18...

Страница 4: ...ND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY WARNING To reduce risk of inju...

Страница 5: ...ctric shock see installation instructions and consult a professional electrician on how to bond pump Also contact a licensed electrician for information on local electrical codes for bonding requireme...

Страница 6: ...manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve po...

Страница 7: ...the power consumption is greatly affected by the speed of the pump Lowering the speed of the pump can drastically reduce the power that is consumed Below are some of the major benefits of running the...

Страница 8: ...rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling 4 2 Pump Mounting Install pump on a level concrete s...

Страница 9: ...shock turn OFF power to pump before working on electrical connections Fire Hazard match supply voltage to pump nameplate voltage Insure that the electrical supply available agrees with the pump s volt...

Страница 10: ...ing at an appropriate flow rate to operate the other equipment as defined by the timers set in the Timer Menu See section 6 7 4 10 Remote Control Wiring Operation The JVS185S and JVS270S pumps can be...

Страница 11: ...nd motor drive RS485 terminal block and user interface PCB Use multi conductor jacketed cable suitable for the installation location The cable must be routed through one of the left side conduit openi...

Страница 12: ...Page 12 of 32 IS3206VSP3J Rev A Figure 4 12 3 Wall Mounting the Interface...

Страница 13: ...on will use the remote stop feature of the drive connect the digital input terminals to the remote stop switch as shown in the Remote Stop Wiring diagram See section 5 5 7 Wiring for remote control an...

Страница 14: ...WILL CONTINUE RUNNING IN THE EVENT OF COMMUNICATION LOSS When inputs are activated via wire jumpers the pump will respond to a communication loss after a 4 minute delay as follows 1 No inputs connect...

Страница 15: ...F ON OFF ON OFF Aux 6 OFF OFF ON ON OFF Aux 7 OFF ON ON ON OFF Aux 8 OFF OFF OFF OFF ON Aux 9 OFF ON OFF OFF ON Aux 10 OFF OFF ON OFF ON Aux 11 OFF ON ON OFF ON Aux 12 OFF OFF OFF ON ON Aux 13 OFF ON...

Страница 16: ...pump is remotely controlled When inputs INP1 3 are activated via the pool control relay contacts timer speeds 1 8 are selected according to the following table see section 6 7 Timer Speed INP1 Status...

Страница 17: ...to Start Up If it is necessary to perform a water pressure test prior to initial use to ensure plumbing system is functioning properly then the following criteria should be maintained for this test 1...

Страница 18: ...T add chemicals to pool spa system directly in front of pump suction Adding undiluted chemicals may damage pump and voids warranty ATTENTION Before removing strainer cover 1 STOP PUMP before proceedin...

Страница 19: ...esume normal operation 4 Quick Clean QUICK CLEAN is a mode intended for use when the pool will be cleaned with a suction side vacuum 6 4 Menu Outline 1 Configuration Menu see section 6 6 for basic pro...

Страница 20: ...buttons for several seconds to unlock Configuration Menu 2 Use to enter Configuration Menu 3 4 Select language for all displayed messages Move to next menu item 5 Use to change clock setting Use if cl...

Страница 21: ...screen is not shown 14 Use to enable or disable password protection Move to next menu item 15 Use to set password timeout Move to next menu item Note This sets the amount of time from the last button...

Страница 22: ...ump is being controlled by a third party pool control the pump display can be locked by the password however the pump will respond to any and all commands being sent from the pool control Buttons Scre...

Страница 23: ...Timer 2 until 2 00 pm Default setting for Timer 1 is to start at 12 00 am and end at 11 45 pm When Remote Control Mode is set to Relay Control the speed for Timer 1 may be set to 0 rpm to allow the p...

Страница 24: ...r status messages as well as the amount of time that has elapsed since the condition occurred See section 11 2 for more detail 6 10 Stop Resume Screen 1 2 Note When Stop Resume is pressed at any time...

Страница 25: ...y shaft seals must be replaced due to wear or damage Replace with genuine seal assembly kit See Shaft Seal Change Instructions in this manual 8 Storage Winterization WARNING Separation Hazard Do not p...

Страница 26: ...the motor assembly out of the pump strainer housing item 3 exposing the diffuser item 9 Remove the two diffuser screws item 7 and pull the diffuser item 9 off of the seal plate item 15 to expose the...

Страница 27: ...nd onto the seal plate item 15 aligning the three pins on the diffuser item 9 with the three holes on the seal plate item 15 Replace the two diffuser screws item 7 9 6 Replacing the Motor Assembly 13...

Страница 28: ...1 13B SPX4000SAV Shaft Seal Assembly Viton 1 14 SPX3200T Housing O Ring 1 15 SPX3200ELB Seal Plate 1 16 SPX3200Z211 Housing Insert Seal Plate Spacer Kit 1 17 SPX3200Z3 Housing Bolt 1 18 SPX3200Z5 Moto...

Страница 29: ...ainer housing cover or the skimmer cover Clean the basket and refill the strainer housing with water Tighten the cover 5 Suction side clogged Contact a qualified repair professional You should have 5...

Страница 30: ...sent Check ambient temperature and verify against motor nameplate 50 C 122 F Check System Drive overload Indicates that motor current is too high Check impeller diffuser shaft seal and motor for any i...

Страница 31: ...Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequ...

Страница 32: ...JACUZZI is a registered trademark of Jacuzzi Inc 2020 Jacuzzi Inc All rights reserved...

Отзывы: