Page 16 of 32
IS3206VSP3J Rev-A
Connection wire must be rated for a minimum of 300V. Inputs are rated to accept a low voltage supply of 18-30 VAC, 9-
30 VDC, 50/60 Hz. The “+12V” and “COM” terminals may be used as a low voltage supply, however, these terminals also
supply power to the user interface, so care must be taken when connecting to these terminals to ensure proper operation
of the user interface. DIP switch #1 must be “ON”.
This pump can be controlled from third party pool controls that are not software compatible using relay contacts to select
the speeds set in the Timer Menu (see section 6.7). In addition to this section you may also consult the applicable pool
control installation manual for electrical connection details. Once installed, Remote Control Mode must be set to Relay
Control in the pump Configuration Menu (see section 6.6). Preset Speeds 1-4 and Quick Clean are disabled when the pump
is remotely controlled. When inputs INP1-3 are activated via the pool control relay contacts, timer speeds 1-8 are selected
according to the following table (see section 6.7):
Timer
Speed
INP1
Status
INP2
Status
INP3
Status
1
OFF
OFF
OFF
2
ON
OFF
OFF
3
OFF
ON
OFF
4
ON
ON
OFF
5
OFF
OFF
ON
6
ON
OFF
ON
7
OFF
ON
ON
8
ON
ON
ON
The number of speeds available depends on the number of auxiliary relays used as noted below:
1.
Filter pump relay plus 1 auxiliary relays allows control of 2 speeds
2.
Filter pump relay plus 2 auxiliary relays allows control of 4 speeds
3.
Filter pump relay plus 3 auxiliary relays allows control of 8 speeds
5.4.
Wall Mounted Digital Control Interface Wiring (Optional)
Figure 5.4-1
Connection wire must be rated for a minimum of 300V, and may be up to 500 feet in length. Use removable 4-position
terminal block connectors for wiring connection to interface and motor drive PCB’s taking care to note the wire colors
and corresponding numbers next to the connectors. Terminal block must be installed with screws facing up to ensure
proper connection. DIP switch #1 must be “ON”.