CARE AND MAINTENANCE OF STEAMPRO STEAM GENERATORS
Maintenance of the Steampros includes flushing periodically and visually inspecting for water leaks.
To drain the units:
1. Turn OFF power to the unit.
2. To gain access to the SteamPro units, open the center panel door. To do so, open the screw cover and remove
the screw. Unplug power cords from the SteamPro units and disconnect all plumbing. Remove the SteamPro units
from their mounting.
3. Flush the tanks out; the drain plug can be removed with an 8 mm hexagonal wrench. Reinstall the steam
generators. (Do NOT operate the steam generators without the water supply ON as permanent damage to
the generators will occur.)
4. Turn ON the water supply and check for leaks.
5. Close door and reinstall door bolt.
6. Turn ON power to the unit.
POWER SUPPLY CORD
3/8" COPPER TUBING
FROM 3/8" SUPPLY FITTING
FROM STEAM
FITTINGS
ON BATH
HOT WATER SUPPLY
COLD WATER SUPPLY
CABLE TIES
230V OUTLET