Page 18
J-400 Series
5.
add start-up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi spa dealer. See Section titled “Water Quality Maintenan
ce”
(page
) for general guidance.
warnInG:
rIsK OF POIsOnInG Or DeaTH.
Never leave chemicals opened and accessible to anyone. Use
chemicals according to the vendors instructions. Always store
chemicals in a safe and/or locked location. Keep away from
and out of reach of children.
!
6.
establish a stable sanitizer reading
Establish a stable sanitizer reading between 3.0-4.0 ppm chlorine
or 2.0-4.0 ppm bromine. To ensure healthy water conditions, always
maintain a constant sanitizer reading within the levels recommended
by the Association of Pool and Spa Professionals/USA printed on the
inside cover of this manual.
If sanitizer levels cannot be stabilized,
perform the Decontamination Procedures on the following page.
note:
The “Decontamination Procedure” should also be used after
the spa has been “Winterized” (sec. 14.7, page
without power for an extended period.
7.
set spa To Heat
To warm spa water to a comfortable
temperature, follow these steps:
The LCD display on the control panel
•
displays the actual temperature of the spa
water. Press either the
uP
or
DOwn
button
on the Navigational Quad Keypad to increase or decrease
the water
temperature by 1 degree.
The heater will
•
turn off 1 degree above set temperature and turn on 1
degree below set temperature.
Important Heater Details:
The maximum temperature for which the spa can be set is 104 °F
•
(40 °C) and the minimum is 80 °F (27 °C).
For North American spas: With a 50 amp service, turn off one
•
of the jet pumps to operate heater. With a 30 amp service, turn
off both jet pumps to operate heater. With a 60 amp service, the
heater will operate with both jet pumps on.
Setting the thermostat at maximum will not accelerate the heating
•
process. This will only result in a higher ultimate temperature.
The heater operates until the water reaches
•
1 degree above the
programmed “set temperature”, then turns off. The heater will
reactivate after the water cools to approximately 1 degree below
the “set temperature.”
UP
DOWN
RIGHT
LEFT
SPLASH
Содержание J-400 Series
Страница 1: ...Owner s manual J 4 0 0 S e r i e s J 460 J 465 J 470 J 480 2530 442W Rev D...
Страница 6: ......