J-200
All North American J-235/J-245/J-275/J-280 Models (60 Hz)
240V/40A*
240V/50A**
240V/60A***
Circuit Breaker (2-Pole):
40A
*
50A
**
60A
***
Number of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
*
In 40A configuration, the heater
will not operate
while either jets
pump is running in high speed.
Note: pump 2 runs only in high
speed.
**
In 50A configuration, the heater
will not operate
while both jets
pumps are running in high speed.
This is the factory setting.
Note: pump 2 runs only in high speed.
***
In 60A configuration the heater
will operate
while both jets pumps
are running in high speed.
Export J-235/J-245/J-275/J-280 Models (50 Hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A
*
30A
**
40A
***
Number of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
*
In 20A configuration, the heater
will not operate
while either jets
pump is running in high speed.
This is the factory setting.
Note:
pump 2 runs only in high speed.
**
In 30A configuration, the heater will
operate
while one jets pump is
running in high speed.
Note: pump 2 runs only in high speed.
***
In 40A configuration the heater
will operate
while both jets pumps
are running in high speed.
Export J-210 Models (50 Hz)
230V/20A*
230V/30A**
Circuit Breaker:
20A*
30A**
Number of Wires:
3
3
Frequency:
50 Hz
50 Hz
Current Draw:
15A
21A
*
In 20A configuration, the heater
will not operate
while the jets
pump is running in high speed.
This is the factory setting
**
In 30A configuration, the heater
will operate
while the jets pump is
running in high speed.