J-200
120/240 Volt Convertible Models
A spa connected to a 120 VAC electrical service must be located close
enough to a grounded, grounding-type electrical outlet so that the
included 10 feet (3m) power cord can be plugged directly into it.
DO NOT
USE AN EXTENSION CORD
as this could cause damage to the spa’s
equipment due to insufficient voltage. The power supplied to this spa
must be a dedicated circuit with no other appliances or lights sharing the
power provided by the circuit.
6.0 Power Requirements
Jacuzzi spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service listed
below. Minor circuit board modifications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
Note:
Refer to pages 48-51 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
All North American J-210 Convertible Models (60 Hz)
120V/15A†
240V/30A†
240V/40A
‡
Circuit Breaker:
15A†, 1-Pole 30A†, 2-Pole 40A
‡
, 2-Pole
Number of Wires:
3 (15A GFCI
Cord US
Only*)
4 (Hard Wire
Only)
4 (Hard Wire
Only)
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
12A
21A
30A
* All Canadian spas must be hard wired per CSA Canadian standards
(page 8).
†
In 15A/30A configuration, the heater
will not operate
while the jets
pump is running in high speed.
The factory setting is 120V/15A.
‡
In 40A configuration, remove jumper JP1-2 on the board, to allow the
heater to
operate
when the jets pump is running in high speed.
CAUTION (For 4-wire 240 VAC Heater Operation): Move the red
wire on the main terminal strip (TB1) from position #1 to position
#3. Make certain wires are connected exactly as shown in Figure
before applying power
. Failure to do so will result in
damage to the circuit board and/or related components and void
the manufacturer’s warranty.