J-200 Series
10.7 Air Controls
Certain jet systems have their own air control. Each control intro-
duces air into the water lines that supply that specific jet group.
Simply turn the air control of choice counterclockwise to open or
clockwise to close. To minimize heat loss, all air controls should be closed when
the spa is not in use.
11.0 Automatic Filtration Cycles
The control system activates a programmable “standard” or “economy” filtration
cycle to remove debris from your spa. These cycles use the low speed jets pump
1 and filter cartridge to quickly clear “skim” the water of debris and minimize
their “bathtub ring” affect while the spa is in use or during a programmed filter
cycle. Models equipped with the optional 24-hour circulation pump offer the
added benefit of 24-hour filtration for pennies a day!
Apart from their filtration benefit, each filtration mode also effects the operation
of the spa heater. Refer to sections 11.1 and 11.2 for details.
11.1 Standard Filtration/Heating Modes For Models Without Circulation
Pump Option (All Models)
Standard filtration/heating modes (F1-F3) are typically selected by customers in
cold climates where heat up times are extended due to lower ambient tempera-
tures. In either of these modes, the water temperature is regulated by the set
temperature, low-speed jets pump 1 and heater which turns on as needed. After
the programmed set temperature is reached, the heater and low speed pump
turn off, only to turn back on during a heat call or during the next programmed
filtration/heating cycle.
11.2 Standard Filtration/Heating Modes For Models With Circulation
Pump Option (J-230, J-270 & J-280 Only)
Standard filtration/heating modes (F0-F3) are typically selected by customers in
cold climates where heat up times are extended due to lower ambient tempera-
tures. In either of these modes, the water temperature is regulated by the set
temperature, 24-hour circulation pump and heater which turns on as needed.
After the programmed set temperature is reached, the heater turns off and the
circulation pump continues to operate 24-hours to filter and clean your spa.
11.3 Economy Filtration/Heating Modes (All Models)
Economy filtration/heating modes (F4-F6) are typically selected by customers
in warm climates where heat up times are minimized due to higher ambient
temperatures. In either of these modes, the water temperature is regulated by
the set temperature, low-speed pump or optional circulation pump, and heater
24