J-200 Series
All North American J-210 & J-220 Convertible Models (60Hz)
120V/15A†
240V/30A†
240V/40A
‡
Circuit Breaker:
15A†, 1-Pole
30A†, 2-Pole
40A
‡
, 2-Pole
Number of Wires:
3 (15A GFCI
Cord US Only*)
4 (Hard Wire
Only)
4 (Hard Wire
Only)
Frequency:
60Hz
60Hz
60Hz
Current Draw:
12A
21A
30A
* All Canadian spas must be hard wired per CSA Canadian standards. (page 4)
†
In 15A/30A configuration, the heater
will not operate
while the jets pump
is running in high speed.
The factory setting is 120V/15A.
‡
In 40A configuration, remove jumper JP1-2 on the board, to allow the heater
to
operate
when the jets pump is running in high speed.
CAUTION (For 4-wire 240 VAC Heater Operation): Move the red wire
on the main terminal strip (TB1) from position #1 to position #3. Make
certain wires are connected exactly as shown in Figure-D (Page 15)
before applyng power. Failure to do so will result in damage to the circuit
board and /or related components and void the manufactures’s warranty.
Export J-270 & J-280 Models (50Hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A
*
30A
**
40A
***
Number of Wires:
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
15A
23A
29A
*
In 20A configuration, the heater
will not operate
while either jets pump
is running in high speed.
This is the factory setting.
Note: pump 2 runs
only in high speed.
**
In 30A configuration, the heater will
operate
while one jets pump is run-
ning in high speed.
Note: pump 2 runs only in high speed.
***
In 40A configuration the heater
will operate
while both jets pumps are
running in high speed.
11