7.0  Electrical Wiring Instructions

IMPORTANT NOTICE: 

The electrical wiring of this spa 

must meet the requirements of the National Electrical 

Code/USA (NEC) and any applicable state or local codes. 

The electrical circuit must be installed by a qualified electrician and 

approved by a local building/electrical inspection authority.

1. 

Dedicated 230V-240V models must be permanently connected 

(hard-wired) to the power supply

. No plug-in connections or 

extension cords are to be used in conjunction with the operation 

of this spa. Supplying power to the spa which is not in accordance 

with these instructions will void both the independent testing agency 

listing and the manufacturer’s warranty.

2.  The power supplied to this spa must be a dedicated circuit with no 

other appliances or lights sharing the power provided by the circuit.

3.  To determine the current, voltage and wire size required, refer to 

Section 6.0 “Power Requirements” (page 12).

•  Wire size must be appropriate per NEC/USA and/or local codes.

•  We recommend type THHN wire.

•  All wiring must be copper to ensure proper connections. 

Do not use 

aluminum wire.

•  When using wire larger than #6 (10 mm²), add a junction box near 

the spa and reduce to short lengths of #6 (10 mm²) wire to connect 

to the spa.

4.  The electrical supply for this product must include a suitably rated 

switch or circuit breaker to open all ungrounded supply conductors 

to comply with Section 422-20 of the National Electrical Code/USA, 

ANSI/NFPA 70. The disconnecting means must be readily accessible 

to the spa’s occupant but installed at least 5 feet (1.5m) from spa 

water.

5.  The electrical circuit supplied for the spa must include a suitable 

ground fault circuit interrupter (GFCI) as required by NEC/USA Article 

680-42.

6.  To gain access to the spa’s power terminal block, remove the screws 

securing the synthetic cabinet panel under the control panel (Figure 

A). Then remove the four control box door screws and door (Figure B).

7.  Select the power supply inlet you want to use (Figure A). Feed power 

cable to control box, then install it through the large opening provided 

in the bottom side of the box.

13

Содержание J-100

Страница 1: ...J 100 COLLECTION OWNER S MANUAL DOMESTIC 6530 592C Rev A...

Страница 2: ...ree Chlorine 3 0 4 0 ppm Free Bromine 2 0 4 0 ppm Total Alkalinity 100 150 ppm Calcium Hardness 150 250 ppm TO DECREASE RISK OF INFECTION OR DISEASE Always maintain your spas filter as outlined below...

Страница 3: ...10 0 Operating Instructions 22 10 1 Setting Water Temperature 22 10 2 Activate Jet Pumps 23 10 3 Multi Colored LED Light System Operation 23 10 4 Adjusting Individual Jet Flow 23 10 5 Selecting Desire...

Страница 4: ...lays SN2 34 14 5 Panel Flashes FL1 or FL2 34 14 6 Panel Displays OH 35 14 7 Panel Displays 35 15 0 Troubleshooting Procedures 35 15 1 None of the Components Operate e g Pump Light 35 15 2 Pump Does No...

Страница 5: ...herein 2 0 FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasona...

Страница 6: ...drowning or severe injury Never use the spa unless all suction guards filter filter lid or skimmer assembly are installed to prevent body and or hair entrapment Never operate or use the spa if the fi...

Страница 7: ...s required by NEC Article 680 42 4 WARNING RISK OF SEVERE INJURY OR DEATH Extreme caution must be exercised to prevent diving or jumping into the spa or slipping and falling which could result in unco...

Страница 8: ...se may lead to unconsciousness with the possibility of drowning 7 WARNING RISK OF SEVERE INJURY OR DEATH Prolonged immersion in a spa may be injurious to your health Observe a reasonable time limit wh...

Страница 9: ...supervision or instruction concerning use of the appliance by a person responsible for their safety 12 NOTE This spa is not intended nor designed to be used in a com mercial or public application The...

Страница 10: ...sembly This has been reported in persons who when submerge themselves underwater allowing hair to come close and or within the reach of the suction fittings suction covers or skimmer assembly Keep hai...

Страница 11: ...vers or skimmer assembly Never allow children to play or get near the suction fittings suction covers filter filter lid or skimmer assembly 3 2 Hyperthermia Prolonged immersion in hot water may induce...

Страница 12: ...ithin 10 feet 3m of the spa shall be bonded to the equipment grounding buss with copper conductors not smaller than No 6 AWG 10 mm 5 SAVE THESE INSTRUCTIONS 3 4 General Electrical Safety Instructions...

Страница 13: ...uctural Engineer with experience in this type of application The spa must be installed in such a manner as to provide drainage away from it Placing the spa in a depression without provisions for prope...

Страница 14: ...tallation to provide full access to the entire spa Please take this into consideration when placing the spa in a deck or enclosed by a surrounding Consider locating your spa away from any reflective s...

Страница 15: ...not following these guidelines or any improper installation not in accordance to local codes or authorities is not covered under the spas warranty Please consult your local state or city building ord...

Страница 16: ...ets pump is running in high speed Note pump 2 runs only in high speed In 50A configuration the heater will not operate while both jets pumps are running in high speed This is the factory setting Note...

Страница 17: ...be appropriate per NEC USA and or local codes We recommend type THHN wire All wiring must be copper to ensure proper connections Do not use aluminum wire When using wire larger than 6 10 mm add a junc...

Страница 18: ...ontrol box door and screws and reinstall the cabinet side panels Figure A Equipment Area Note Equipment location such as pumps drain heater etc varies by model 1 Control Box 5 Pump Drain Plug 2 Power...

Страница 19: ...hed at the factory you may want to treat it with a specially formulated spa cleaner Consult your authorized Jacuzzi dealer for additional information prior to filling spa Remove filter cover then remo...

Страница 20: ...art Up Chemicals Add the spa water chemicals as recommended by your authorized Jacuzzi dealer See Section 13 0 Water Quality Maintenance page 31 for general guidance WARNING RISK OF POISONING OR DEATH...

Страница 21: ...ow speed and jets pump 2 must be turned off to operate the heater For Export spas connected to a 20 amp service jets pump 1 must be set to low speed and jets pump 2 must be turned off to operate the h...

Страница 22: ...r chemical maintenance 10 Leave spa cover open during this step to allow excessive chemical vapors to exit spa protecting pillows and plastic knobs from chemical attack If spa is indoors open doors an...

Страница 23: ...ed for any reason especially if while the cover is open and accessible to small children and animals To decrease the risk of contracting a waterborne illness e g an infection bacteria or virus and or...

Страница 24: ...d time to turn pump 2 off E Light Button Turns accent lights on in one of three random modes or one of seven solid colors Refer to Section 10 3 page 23 for details F Warmer Button Increases water temp...

Страница 25: ...ct Jets 4 ea 5 Classic Euro Jets 18 ea 6 Classic Mini Jets 2 ea 7 Classic Luxury Jets 9 ea 8 Classic Whirl Jets 2 ea 9 Waterfall with flow rate control lever 10 Cup Holders 10 ea 11 Filter skimmer wit...

Страница 26: ...a s thermostat provides optimum control of water temperature The temperature set point set temperature can be adjusted from 65 104 F 18 40 C To raise the set temperature press the WARMER button To low...

Страница 27: ...ps You must press the light button within 3 seconds of any off condition or the light sequence will revert back to Random Fade mode when reactivated Anytime the spa light is manually activated it will...

Страница 28: ...the water temperature is regulated by the set temperature only during a programmed filtration heating cycle The heater will turn on only when there is a heat call during a programmed filtration heatin...

Страница 29: ...le every 6 hours Lock Modes L1 L3 When in a lock mode the display will flash between the temperature and the Lock mode number L1 Lock Out disables all spa functions to permit filter cleaning Note The...

Страница 30: ...ction fittings suction covers or pump s be sure that the flow rates are compatible and are in compliance with the VGB Safety Act page 2 Never replace a suction fitting or suction cover with one rated...

Страница 31: ...d a more thorough cleaning to remove imbedded oils and minerals For this we suggest cleaning as illustrated followed by soaking the filter overnight in a plastic container filled with a solution of wa...

Страница 32: ...y from spa If equipped turn valve 2 counterclockwise to open the valve Figure C 4 After spa is drained reinstall drain cap on drain hose fitting until finger tight If equipped turn valve 2 clockwise t...

Страница 33: ...ol B Additional Care and Maintenance Instructions 1 Debris can accumulate on the spa cover Removal of snow or other debris will help to avoid breakage of the foam cores 2 Be sure to lock the cover str...

Страница 34: ...ary to get the water out of the recessed seating areas and into the footwell such as a wet dry vacuum 3 Turn the waterfall valve to the open position to allow the water in the plumbing lines to drain...

Страница 35: ...investment For specific guidance on maintaining water quality consult your Authorized Jacuzzi dealer who can recommend appropriate chemical products for sanitizing and maintaining your hot tub WARNIN...

Страница 36: ...ws and plastic knobs from chemical attack WARNING RISK OF PERSONAL INJURY DROWNING OR ENTRAPMENT Never leave your hot tub unattended for any reason while the cover is open and accessible especially to...

Страница 37: ...he jets pump 1 is activated Proper water flow is inhibited or the pressure switch has malfunctioned A flashing FL2 display means the pressure switch is malfunctioning closed In either case the heater...

Страница 38: ...insist on genuine Jacuzzi replacement parts 15 1 None of the Components Operate e g Pump Light Check the following 1 Is there power to the spa 2 Is the household circuit breaker tripped 3 Contact your...

Страница 39: ...e settings to see if your spa is in economy filtration heating mode page 24 Should checking the above steps fail to correct the problem please call your dealer so that they may arrange service We buil...

Страница 40: ...mplies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any inteference received including...

Страница 41: ...Heater 2 7 kW 230 VAC WHT BLK LED Lighting System DCU Logic Jumper Settings JP1 1 2 ON 20A Logic JP1 1 2 OFF 30A Logic JP1 3 4 ON 2 Pump Operation JP1 3 4 OFF 1 Pump Operation JP1 5 6 ON 40A Logic Rem...

Страница 42: ...J 100 38...

Отзывы: