background image

13

Preparations for installation

I

Alimia is provided with a drain, prepared as in

i

1, (detail 1);

i

3, (detail B)

. The Customer must make provisions for a ground

drainage point of suitable dimensions and that can be inspected for
any cleaning.

CAUTION: Before preparing the ground drainage point,
consult the local authority for the regulations that control the
drainage of chemically treated water..

I

For periodic emptying of the spa a hose can be connected to the

drain, then remove the closure cover at the base and screw on the hose
coupler provided

i

3, (detail B)

.

N.B.

To open the valve, you must turn the ring nut anticlockwise

and pull it, therefore if you decide to connect the spa perma-
nently to the ground drainage point, we recommend you install
a valve below, bypassing the valve installed in the factory.

I

The ground drainage point must then be put into position according

to the type of installation chosen.

Alimia can be installed in different ways:

-

Free standing

on the floor or on a specifically prepared base (

i

5

).

-

Semi-built

in, so that only the base of the spa is built-in and there-

fore the side cover panels remain free (

i

6

). In this case, it is nec-

essary to prepare some removable under-frames (in marine plywood,
etc.) that, besides aesthetically completing installation, allow the pan-
els to be removed more easily. Measurements for insertion into the
floor can be taken from the base measurements of the spa (

i

1

).

-

Built in

, with the tub rim at floor level (

i

7

and

8

). In this case, a

base support must be made under the bottom of the tub (in con-
crete and steel beams, (

detail 1

).

Access to the hosing must be ensured and to all other electro-
mechanical parts that are under the tub, for example by making a pas-
sage along the outer perimeter, that is wide enough (about 80cm) to
carry out all electrical and hydraulic connections and any maintenance
operations (

detail 2

). This passage can be closed using removable un-

der-frames (

detail 3

), with suitable supports (

detail 4

).

Drainage for any water stagnation must also be provided (

detail 5

).

Prolonged sun exposure could damage the material of whi-
ch is made the spa shell, due to its capacity to absorb heat (dark
colours in particular). Don't leave the spa to sun exposure
without adequate protection when not in use (cover ther-
mal, gazebo, etc.).
Any damage arising by not following these warnings are not
covered by the guarantee.

I

In any case, a base support must be made that is suitable to hold the

weight of the Alimia model spa , referring to the “Weights” table provided.

I

You can use a garden hose to fill the spa.

For periodic filling, if you decide to connect the spa
hydraulic circuit to the public water system that supplies
drinking water, this connection must be carried out in

compliance with the EN1717 norm, using “AA”, “AB” or
“AD” anti-pollution protection procedures.
For further information, we recommend you contact your
water supply company and/or your plumber.

I

In the case of indoor installation, you must remember that water

evaporation from the spa (especially where high temperatures are in-
volved) can cause very high levels of humidity. Natural or forced ven-
tilation helps to maintain personal comfort and reduce damage to the
building due to humidity.

Jacuzzi Europe refuses all responsibility for any damage caused by
excessive humidity or by overflowing water. Consult a specialist for
indoor installation.

I

Concerning the suitability of the electrical system and of the

connections, refer to the second part of the manual for installation,
use and maintenance (see the chapter on ELECTRICAL SAFETY).

Electrical connections pre-arrangement

The electrical connection can be made as follows:

- single-phase line (220-240V 1~)

- three-phase line consisting of two phase cond

neutral conductor (380-415V 2N~)

- three-phase line consisting of three phase cond

neutral conductor (380-415V 3N~)

The rated power supply voltage of the equipment is

always 220-240V.

The equipment can also be installed in Countries

where the 220-240V voltage is supplied by a two-pha-
se system. For the connection please refer to the in-
struction manual.

I

The installer must in any case use properly protected cables with

a suitable cross-section

(220-240 V 1N~: min. 4 mm

2

; 380/415 V

3N~:min.2,5mm

2

)

, with characteristics not inferior to type H 05 VV-

F.

N.B. The lead sections must take account not only the system's
absorption but also the cable path and the distances, the cho-
sen protection systems and the specific regulations for fixed
electrical systems in force in the country where the spa is in-
stalled. The electrical box terminal board is designed for ca-
bles with sections up to 6 mm

2

.

I

To ensure the degree of protection against splashes of water as

required by standards, and to make connection to the electrical
mains easier, the electrical box is equipped with a cable clamp M32
x 1.5mm.

I

The installer must comply with the above regulations,

as well as

use watertight connectors at connection points and must
guarantee compliance with the specific norms for the sys-
tems engineering that are in force in the country where the
spa is installed. It is mandatory to comply with this in-
struction. Any other procedure is prohibited.

Содержание alimia

Страница 1: ...zione CONSERVARE CON CURA Instructions for preinstallation KEEP CAREFULLY Fiche tecnique de pre installation GARDEZ SOIGNEUSEMENT Vorinstallationsblatt SORGF LTIG AUFBEWAHREN Ficha t cnica de preinsta...

Страница 2: ......

Страница 3: ...Italiano 10 English 12 Fran ais 15 Deutsch 17 Espa ol 20 23 Alimia Index...

Страница 4: ...4 212 216 22 5 8 76 3 5 1 2 Alimia wood Alimia synthetic wood Alimia built in 216 x 216 76 212 16 5 8 5 212 202 65 5 90 76 16 8 5 65 5 90 202 76 212 16 5 8 5 202 65 5 90 1 i cm...

Страница 5: ...5 Alimia wood Alimia synthetic wood Alimia built in 2 i...

Страница 6: ...6 76 cm 5 8 B B 3 4 1 1 2 2 3 3 i...

Страница 7: ...ell impianto size based on table Maximum absorption of the system dimensionner en se rapportant au tableau Absorption maximale de l installation auf der Grundlage der Tabelle maximale Aufnahme der Anl...

Страница 8: ...8 12 cm Alimia synthetic wood synthetic wood wood OK 6 i 5 i...

Страница 9: ...9 208 cm 5 1 4 3 3 2 2 4 5 7 i 8 i...

Страница 10: ...la ghiera in senso antiora rio e tirarla nel caso quindi si decida di collegare in modo fisso la spa al pozzetto di scarico consigliabile installare una valvola a valle by passando la valvola montata...

Страница 11: ...itare il collegamento con la rete elettri ca sulla cassetta elettrica stato montato un pressacavo M32 x 1 5 mm I L installatore dovr rispettare le suddette prescrizioni nonch uti lizzare raccordi stag...

Страница 12: ...ges to ensure optimum water fil tering the filtering surface is equal to 9 3 m2 Maximum absorption of the system The electrical system that powers the spa must absolutely be sized for maximum consumpt...

Страница 13: ...eights table provided I You can use a garden hose to fill the spa For periodic filling if you decide to connect the spa hydraulic circuit to the public water system that supplies drinking water this c...

Страница 14: ...For electrical connections the installation of a multiple pole sec tion switch is compulsory i4 It must be positioned in a place that complies with safety regulations and in any case which cannot be r...

Страница 15: ...teur de la base et en vissant le rac cord avec garniture fournie i3 d tail B NOTE Pour ouvrir la vanne il est n cessaire de tourner la bague dans le sens contraire des aiguilles d une montre et de la...

Страница 16: ...s de protection choisis et des normes sp cifiques pour les installations lectriques pose fixe en vigueur dans le pays o est install e la mini piscine spa Le bornier de la bo te lectrique est pr vu pou...

Страница 17: ...vorgenommenen Installation Technische Merkmale Im Whirlpool spa Mod Alimia i1 i 2 ist mit zwei Pumpen f r die Wassermassage mit jeweils 2 PS und einer Umlaufpumpe ausgestat tet Zur Gew hrleistung ein...

Страница 18: ...mtliche Wartungsarbeiten durchgef hrt werden k nnen Detail 2 Dieser Kanal kann durch entfernbare Trittbretter abge deckt werden Detail 3 die ihrerseits auf entsprechenden Ab st tzungen lagern Detail...

Страница 19: ...m Grund permanent ohne Zwischenverbindungen an das Stromversorgungsnetz und an die Erdungsanlage anzuschlie en Die elektrische Anlage der R umlichkeit ist mit ei nem Differentialschalter 0 03 A und ei...

Страница 20: ...o i3 det B NOTA para abrir la v lvula se debe girar el anillo en sentido con trario al de las agujas del reloj y tirar de l en caso de que deci da conectar de manera fija la spa al colector de desag e...

Страница 21: ...icas estables vigentes en el pa s donde se va a instalar la spa La bornera de la caja el ctrica est predispuesta para cables de secci n de hasta 6 mm2 I Para garantizar el grado de protecci n contra l...

Страница 22: ...osiciones de ley y las normas vigentes en el pa s donde se ins tala la spa I Para la conexi n equipotencial prevista por las normas nacionales es pec ficas el instalador deber utilizar el borne previs...

Страница 23: ...zi Europe S p A v spa Alimia i 1 i 2 2 2 1 2 9 3 2 spa 3 6 1 I I I I Alimia i1 1 i3 B I spa i3 B spa I Alimia i5 spa i6 spa i1 a i7 8 1 80 2 290 1370 1650 1940 2 2 3 10 626 50 60 x 26 5 75 k k 230 x j...

Страница 24: ...spa spa I spa A limia I spa spa EN 1717 AA AB AD I spa Jacuzzi Europe I I 220 240 1 380 415 2N 380 415 3N I 220 240 I 220 240 I 220 240 V 1N min 4 mm2 380 415V3N min 2 5mm2 H 05 VV F spa 6 2 I M32 x 1...

Страница 25: ...25 Alimia EN 60335 2 60 EN 61000 EN 55014 I I spa I 0 03 TE ST I i4 spa I I spa spa I EN 60335 2 60 i4 I EN 62471 2009...

Страница 26: ......

Страница 27: ......

Страница 28: ...irezione e Coordinamento Jacuzzi Brands Corp USA S S Pontebbana km 97 200 33098 Valvasone PN ITALIA Tel 39 0434 859111 Fax 39 0434 85278 www jacuzzi eu info jacuzzi it Jacuzzi Spa Bath Ltd Woodlands R...

Отзывы: