8/67
IDENTIFICATION
(Part no. - Description)
FILTER (Mesh)
NOZZLE
TYPE
(1197536) JEF 11002
YELLOW
(1197476) JSF 11002
YELLOW
(1197535) JEF 110015
GREEN
80 (Zinc yellow)
50(Gentian blue)
50(Gentian blue)
80 (Zinc yellow)
50(Gentian blue)
50(Gentian blue)
50(Gentian blue)
50(Gentian blue)
50(Gentian blue)
50(Gentian blue)
50(Gentian blue)
50(Gentian blue)
80 (Zinc yellow)
80 (Zinc yellow)
50(Gentian blue)
(1197475) JSF 110015
GREEN
(1197537) JEF11003
BLUE
(1197477) JSF11003
BLUE
Herbicides
30
30
0.49
0.49
30
30
0.65
0.65
30
30
0.58
0.98
APPLICATION
PRESSURE
(psi)
FLOW RATE
(l/min)
(1197565) JHC 8002
YELLOW
45
0.80
(1198892) JHC 8004
RED
45
1.60
(1198893) JHC 8005
BROWN
45
2.00
(1197486) JDF 04
RED
(1197497) JAI 120015
GREEN
(1197488) JDF 06
GREY
(1197501) JAI 12003
BLUE
(1197487) JDF 05
BROWN
(1197499) JAI 12002
YELLOW
15
20
0.92
0.42
15
20
1.15
0.57
15
20
1.39
0.85
Fungicide,
insecticide
and
foliar
fertilizers
Herbicides
and
foliar
fertilizers
Herbicides
Herbicides
*Approximate data based on a spray swath for unique nozzles at
50 cm height of the target.
8. Operating Instructions
The following steps describe how to safely use the sprayer.
8.1. Select the correct nozzle
8.2. Calibration of battery powered knap-
sack sprayer
PROCEDURE
1.
USING CALIBRATOR BOTTLE (OPTIONAL)
2.
Hold the lance at the working height and spray to mea-
sure the application band width.
3.
Based on the band width, calculate the total walking dis-
tance required to spray the desired area. Use the chart as
shown next.
Band
width
Lance
Cover
Filter
Nozzle
Nozzle cap
Calibrator
bottle
• Attach the calibrator bottle to the lance as shown:
• Remove the cap, nozzle and filter.
• Mount the calibrator cover to the lance.
• Reinstall the filter, nozzle and cap.
• Screw the calibrator onto the cover.
Record the time it takes to
walk 25 m²
Simulate the spraying of 25 m²
1.
Hold the lance at the normal working height and spray
into the bottle while walking the distance required to
spray an area corresponding to 25 m².
2.
Place the bottle on a level surface and observe the liquid
level visible through the side of the bottle. Match the
liquid level to the corresponding scale on the calibrator
bottle.
3.
Empty the bottle and repeat this operation to determine
the average of two or more readings.
Band width
(m)
0.5
0.7
1.0
1.2
1.5
Distance to
walk (m)
50.5
35.7
25.0
20.8
16.7
NOTE: For the volume in liters per bushel (L / alk), simply multiply
the value obtained in liters per hectare (L / ha) by 2.42.
NOTE: This sprayer is packaged with the Blue Adjustable Cone
nozzle fitted in the lance. Other nozzles mentioned in this manu-
al are optional, so they do not accompany this sprayer.
8.3. Filling the spray tank with pesticides.
1.
Read carefully the chemicals manufacturer’s labels;
2.
Put 5 liters of water in a bucket and add the chemical
product;
3.
Stir until it becomes an homogeneous mixture;