22/43
8.3. Adjusting the joystick
The joystick can be adjusted to be more ergonomic and improve the application
angle, placing the operator’s arm in a more vertical and more relaxed position.
Therefore, the closer the joystick is position to the hose, the better the application.
For that, loosen the screws, and reinsert them in the support handle as desired.
8.4. Adjusting the harness
The equipment tank has an anatomic shape to provide more comfort to the op-
erator. The equipment can be correctly adjusted to the operator’s body through
simple harness adjustments.
Once the equipment is assembled, attach the application lance to the support
handle to make transport easier and prevent damages to its components.
Joystick
cables
Hose clamps
Battery
•
Use the remaining hose clamps to secure the cables to the battery to prevent
them from getting loose, and damaged during use;
Joystick
Use the strap and the buckle clip to adjust the harness as desired.
Trigger
Joystick panel
On/Off button
Function selector button
Battery charge indicator
Trouble indicator
Spreader
speed
indicator*
Spot application
indicator
Continious/in-row/
area application
indicator
Calibration indicator
9. Before Operating the Equipment
9.1. Joystick Functions
The joystick function is to turn the equipment on and off as well as to calibrate it
and apply desired dosages. Check below how to operate it:
Support handle
OBS*.: The accessory AG-95 Electric Spreader is sold separately.
"On/Off" button
Press the “on/off” button once to turn the equipment on.
Press and hold the button to turn the equipment off.
Once the equipment is on, press the button once to increase the spreader speed,
and press it again to reduce it. The spreader speed indicator light will blink more
intensely when the speed increases.
OBS.: To select Jacto AG-95 Electric Spreader, make sure the accessory is connect-
ed to the joystick.
Function selector button
Press the function button to select between: Spot application or Continuous / In-
row / Area application.
Press and hold to select calibration function.
Trouble indicator
When operating the equipment, the following warnings may be displayed in case
a fault is detected:
•
Insert the battery on the at the bottom of the equipment base. To remove
the battery, press the two snap-on latches, and pull the battery outside the
compartment.
OBS.: Adjusting the equipment so that the tank is higher and allows the applica-
tion lance angle to be less than 45°, improves input applications.
Buckle clip
Strap
•
Close the cover and tighten the screws. Make sure all cover sides are aligned
and sealed;