background image

 

 

www 

|

 jacques.com.au 

Document Number 

|

 JED-0492 

Revision 

|

 1.0 

 Page 12 of 18 

 

1)

 

The relay output may only be connected to an ES1 or a SELV circuit! An ES1 circuit as per IEC/EN/UL 62368-1 or a SELV circuit as per 

IEC/EN 60950-1 must be separated safely from a dangerous electrical circuit (e.g. 230 V or 110 V mains power), e.g. by means of double 
insulation. The ES1 or SELV circuit must not exceed 60 VDC or 42.4 VAC

peak

 (30 VAC

eff

)!

 

 

SAFETY WARNINGS 

 

Observe the country-specific standards for installation, mounting and configuration.  

 

Only use Jacques accessories that comply with the 

product’s technical specifications. 

 

Disconnect the Ethernet cable for any maintenance of the device.  

 

Do not make any modifications to the device. 

 

All external connected circuits shall fulfil the requirements for Electrical Energy Source Class 

1 (ES1) and Limited Power Source (LPS) according to IEC/EN 62368-1.  

 

INSTALLATION INSTRUCTIONS 

 

See 

Mounting Solutions 

for methods of mounting a JIB product. 

 

Jacques JIB and optional accessories shall be installed or replaced by trained and qualified 

personnel only. 

 

Before attempting to install please ensure your package contains the list of specified parts. 

 

Do not install the device 

on unstable walls or on surfaces which cannot support the device’s 

weight. 

 

Make sure the surface mount kit not subject to torsional forces (e.g. on uneven walls).  

 

Avoid mounting unit in direct sunlight.  

 

Connect a network cable into the RJ45 connection located on the front of the product which 

can also be connected to an IEEE 802.3af PoE PSE compliant network switch or 

management device. 

 

Before powering the device, ensure all cables are correctly connected and not damaged.  

 

 

 

Содержание JEM-4

Страница 1: ...JEM 4 JACQUES INTERCOM BOX PRODUCT MANUAL JED 0492 www jacques com au...

Страница 2: ...mplied warranties so the above exclusion may not apply to you Jacques Technologies Pty Ltd acknowledges that information in this publication may be unsuitable in various circumstances and disclaims li...

Страница 3: ...TECHNICAL SPECIFICATIONS 11 SAFETY WARNINGS 12 INSTALLATION INSTRUCTIONS 12 MOUNTING SOLUTIONS 13 AGENCY REGULATORY NOTICES 14 FEDERAL COMMUNICATIONS COMMISSION NOTICE 14 DECLARATION OF CONFORMITY FO...

Страница 4: ...o this document TERM DEFINITIONS ANM Ambient Noise Monitor AU NZS Standards Australia and New Zealand EU European Union FCC Federal Communication Commission IEEE Institute of Electrical and Electronic...

Страница 5: ...el does not fulfill a required formfactor the JIB 4000 will likely provide a solution Figure 1 JIB 4000 Front and Side View FEATURES Balanced microphone level audio input configurable for single ended...

Страница 6: ...nded for factory programming purposes LED INDICATORS PWR When lit indicates the devices internal power rails 5 V d c and 12 V d c are operational STAT Indicates the devices current operational status...

Страница 7: ...www jacques com au Document Number JED 0492 Revision 1 0 Page 7 of 18 CONNECTION DETAILS JIB 4000 REAR CONNECTIONS Figure 3 JIB 4000 Rear Connections...

Страница 8: ...Document Number JED 0492 Revision 1 0 Page 8 of 18 LED CONNECTIONS Figure 4 JIB 4000 LED Rear Connections Pin Signal 1 LED common anode 3 3 V d c 2 LED 1 cathode 3 LED 2 cathode Figure 5 LED connectio...

Страница 9: ...re 6 JIB 4000 Relay Rear Connections Pin Signal 1 Relay 2 Normally Open NO Contact 2 Relay 2 Common COM Contact 3 Relay 2 Normally Closed NC Contact 4 Relay 1 Normally Open NO Contact 5 Relay 1 Common...

Страница 10: ...NNECTIONS Figure 8 JIB 4000 Peripheral Connections Pin Signal 1 Speaker Negative 2 Speaker Positive 3 Audio Ground 4 Audio Input Negative 5 Audio Input Positive 6 Ground 7 Button input 1 8 Button inpu...

Страница 11: ...er Output Level Class D Bridge mode 2 5 W RMS into 4 ohms Output frequency response 3 dB 32 Hz 13 6 kHz Analogue Mic Input Impedance 6 4 k balanced 3 2 k single ended Max Analogue Balanced Mic Input L...

Страница 12: ...nnected circuits shall fulfil the requirements for Electrical Energy Source Class 1 ES1 and Limited Power Source LPS according to IEC EN 62368 1 INSTALLATION INSTRUCTIONS See Mounting Solutions for me...

Страница 13: ...ions optionally available for JIB products Jacques P N Description 52235 Wall Mounting Kit 52236 DIN Rail Mounting Kit 52237 Eurocard Mounting Kit accepts two units Figure 10 Surface Mounting Kit P N...

Страница 14: ...terference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circ...

Страница 15: ...harmonized standards have been applied for the certification of conformity to the guidelines listed above EN 55024 2010 A1 2015 Information technology equipment Immunity Characteristics Limits and met...

Страница 16: ...e recycling of waste electrical and electronic equipment The directive 2012 19 EU on waste electrical and electronical equipment WEEE is applicable in the European Union member states The separate col...

Страница 17: ...r informational purposes and is not legally binding Subject to change technical or otherwise ORDERING INFORMATION The Universal Audio Interface is supplied and shipped with the following components Ja...

Страница 18: ...www jacques com au Document Number JED 0492 Revision 1 0 Page 18 of 18 DOCUMENT REVISION HISTORY REVISION DATE AUTHOR CHANGE DESCRIPTION 1 0 2020 09 28 LM Initial Release...

Отзывы: