9.2
DAILY CHECKS (Every 8 working hours)
Oil Level.
Check level of oil in sump. Remove dipstick
(Located in area B) wipe and replace and check that
oil is up to the maximum mark. Top up with 10W30
if neccesary(A). It is important that this test is
carried out with the engine cold and the vehicle
parked on level ground.
Hydraulic Oil Level.
Check hydraulic oil level in tank. The level of oil
should be maintained halfway up the sight glass (C).
Top up with10W30 hydraulic oil or equivilent if
neccessary. The oil level should be checked cold
with the machine parked on level ground.
IMPORTANT: Absolute cleanliness must be
observed when filling the hydraulic tank. Oil
must be filtered through a 25 micron filter
before entering the hydraulic tank.
Cooling System.
Check coolant level in expansion tank the coolant
level should be between the marks indicated on the
expansion bottle. Top up if neccessary using a 50%
antifreeze solution.
Air Filter.
If working in dusty conditions the air filter element
should be examined and cleaned/replaced every 8
working hours(D).
Cleaning the air filter.
Remove loose dirt from element with compressed air
working from the "clean" to "dirty" side.
Note:
Compressed air must not exceed 6bar, with
the nozzle 50mm away from element. The element
should be replaced after 6 cleanings.
Cooling System.
Check Bug Screen/Radiator & Oil cooler are all
free from dust /debris and there is an un-
interupted air flow to the engine. The screen
should be fitted with the mesh facing the rear of
the machine. Any debris should be removed
with a soft hand brush.