5. Operation

5.1. Switch on Device and H2 Sensor in an area where no traces of H

2

gas are

present. Device On/Off button is located on the top edge of Device (Figure

4). The H2 Sensor On/Off button is located on the top edge of H2 Sensor

(Figure 4).

5.2. Once Device detects the wireless H2 Sensor, the SENSOR CONNECTED

button will be shown in blue color (Figure 5).

5.3. Switch on H2 Sensor pump using the PUMP button (Figure 5) on Device

screen.

5.4. After the H2 Sensor is switched on, initial heating of the sensor is

performed (the system cannot be used during the heat up time). Once the

H2 Sensor is available for work a beep sound begins.

Note:

Please note that initial values of PPM may be above zero due to different factors

such as air humidity or traces of gas trapped inside of the sensor from the previous use. In

such a case, the user can wait several more minutes with the H2 Sensor pump switched

on, until the PPM value will drops to zero. We recommend always keep the pump working

to allow fast air circulation through H2 Sensor. Even if the initial PPM values are above zero

for any reason, it does not limit or prevent performing a leak detection.

5.5. Stream tracer gas under pressure into piping or vessel after closing all

valves and openings which gas can escape through.

5.6. Walk slowly along the pipe or vessels, while directing H2 Sensor towards

the examined structure.

5.7. When H2 gas is detected, PPM value will rise. Walk around the area where

gas is detected to establish where PPM values are the highest. Take PPM

readings using TAKE A READING button (Figure 5) to assist in finding the

area with the highest PPM readings. This area may have the highest

probability of leak (but not always).

5.8. Push on the speaker button (Figure 5) to switch on/off beeping sound used

to assist in leak detection.

5.9. Adjust the brightness of the screen using + and – buttons (Figure 5).

5.10. Clear reading in the reading graph by pressing CLEAR button (Figure 5).

5.11. At the end of the work, switch off the device using the Device On/Off

button on the screen (Figure 5) and wait until the screen switches off.

Switch off H2 Sensor by pressing a Switch On/Off button (Figure 4).

5.12. Clean Sensor filter from large particles using a brush if needed.

R 0 | JUNE 2021 | PAGE 8

Содержание SNIFFER 430

Страница 1: ......

Страница 2: ...USER MANUAL Jacob s MC Table of Contents Table of Contents 2 The use and principal of application 3 Safety and Liability 4 Warranty 4 Technical Specifications 5 Operation 6 Troubleshooting 7 R 0 JUNE...

Страница 3: ...racer gas under pressure into an inspected piping or vessel followed by step by step search for the area where the tracer gas is escaping Tracer gas presence is detected by the H2 Sensor which transfe...

Страница 4: ...Do not immerse in water or sludge 2 5 Do not operate in areas with high dust sand or powder concentration 2 6 Safety instructions related to use storage and transport of tracer gas pressure vessels ho...

Страница 5: ...f improper use change modification or opening of SNIFFER 430 Device H2 Sensor AC adaptor or any of their components 4 Technical Specifications Table 1 summarizes technical specifications of the SNIFFE...

Страница 6: ...7v 3000mAh 18650 battery 1 unit Power adaptor Input AC 100 240v 50 60Hz Output DC12v 5A Electric plug type EU 2 pins Dimensions Total length 800 mm Sensor diameter 60 mm Rubber suction cup diameter 10...

Страница 7: ...SNIFFER 430 USER MANUAL Jacob s MC Figure 3 SNIFFER 430 System Kit R 0 JUNE 2021 PAGE 7...

Страница 8: ...ation through H2 Sensor Even if the initial PPM values are above zero for any reason it does not limit or prevent performing a leak detection 5 5 Stream tracer gas under pressure into piping or vessel...

Страница 9: ...1 Device On Off Device button 2 Device AC adapter power socket 3 Device battery status led 4 Device reset button 5 H2 Sensor On Off button 6 Air outlet 7 H2 Sensor AC adapter power socket 8 H2 Sensor...

Страница 10: ...top edge of H2 Sensor see Figure 4 is blocked Use a small diameter wire to clean the opening Contact service if it does not solve the problem 3 Device shows non zero value when switched on Turn on the...

Страница 11: ......

Отзывы: