SNIFFER
430
USER MANUAL
|
Jacob’s
MC
SNIFFER
430
sensor
Specifications
Gas detector
Hydrogen, H
2
gas
PPM readings resolution
1 PPM H
2
Gas sensor heat up time
1.5-10 minutes (vary under different
environmental conditions)
Gas sensor pump flow rate 1.5 liters/sec
PPM update rate
1 sec
Sensor to Device
communication
Wireless (Bluetooth BLE4), 10-meter
communication distance in open space
Power
Built-in Li-Ion 3.7v 3000mAh 18650 battery (1
unit)
Power adaptor: Input: AC 100-240v 50-60Hz
Output: DC12v 5A
Electric plug type: EU (2 pins)
Dimensions
Total length: 800 mm
Sensor diameter: 60 mm
Rubber suction cup diameter: 100 mm
Operational temperature
range
-10°C to 50°C
Package and scope of
delivery
Specifications
SNIFFER
430
system
SNIFFER
430
system package (Figure 3)
includes:
1.
SNIFFER
430
Device
2.
SNIFFER
430
H2 Sensor
3. AC power adapter
4. Silicon rubber protection case for
SNIFFER
430
Device.
5. Neck strip and hand strip
6. Rugged plastic case
Package dimensions
56 x 23 x 46 cm
Package weight
8.4 kg