![JACLO J-TH34 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/jaclo/j-th34/j-th34_installation-instructions-manual_3172232004.webp)
OCTOBER 3, 2017
jaclo
industries
| 129 Dermody Street Cranford, NJ 07016
p
908.653.4433 | 800.852.3906
f
908.653.1717 | 800.852.4133
JACLO.COM
| PG 4
1" Ø
Max
SAMPLE HOLE IN WALL
TO SHOWERHEAD OR
OTHER PLUMBING
ASSEMBLY
OPTIONAL VOLUME
CONTROL
1" THICK FINISHED
WALL OUTER EDGE
DIVERTER
4-1/4" MAX
TO TUB SPOUT ONLY
[STEP 1]
ROUGH VALVE INSTALLATION
(J-20682/J-20686/J-20688)
1. Position valve assembly per
Figure 5
2. Using appropriate fasteners, mount valve assembly to studs/blocking.
Figure 5
3. Remove diverter cartridge.
Page 6
4. Connect inlet and outlet port piping.
**SEE PAGE 8 FOR PORTS USED/BLOCKED**
5. See “Rough in plumbing and valve flushing”.
Page 9
6. Turn on water supply and flush valve with cartridge removed.
Page 9
7. Turn off water supply and re-install cartridge.
Page 10
8. Turn on water supply and test for leaks and all functions.
9.
Continue on to
Page 11 & 12
Installation Example
Figure 5
Valve Rough Specs
5 3/4"
3 3/8"
Check Stop Access
2X
1/2" or 3/4" NPT
3 1/2"
Cold
Inlet
Hot
Inlet
All outlets require volume
control/diverter or plug (not supplied)
5 3/4"
3 3/8"
1/2" NPT
OUT
5 1/2" REF.
Cold
Inlet
Hot
Inlet
Check Stop Access
2X
INLET
1/2" NPS
3x
3 9/16"
3 9/16"
1 11/16"
Ø1/4"
2x
1 11/16"
B
A
C
C Port
B Port
A Port
5 3/4"
1/2" NPT
3x
3 3/8"
C Port
B Port
1 7/8"
2 5/16"
Check Stop Access
2X
A Port
3/4" 1/2"
Reducing
Bushing
3/4" NPT
3 5/8"
3 5/16"
Cold
Inlet
Hot
Inlet
B
A
C
Extra Outlet requires
volume control or plug (not supplied)
Mounting Holes
"JACLO INDUSTRIES PROPRIETARY INFORMATION"
Dimensions are for reference only.
Jaclo reserves the right to change specifications without notice.
®
®