PROBLEM

POSSIBLE CAUSE

SOLUTION

Water leaks from

shower head / tub

spout when the

volume control is

shut off.

Water is hot or cold

but not mixing.

Can not adjust 

water temperature

properly.

Low flow of mixed

water.

Cold water in nearby

faucet is lukewarm.

Thermostatic valve is

working properly, but

the water is not hot 

enough, but water in 

nearby faucet is hot

enough.

Thermostatic valve is installed

upside down or the supply lines

to the thermostatic valve are

reversed.

Remove trim and make sure the arrows on the check valve / stops are 

facing toward the center of the 

thermostatic valve.

If cartridge spindle rotates more than 270°

(DO NOT FORCE), replace cartridge.

Remove thermostatic cartridge and clean screens.

Refer to installation instruction for setting limit stops.

Set water temperature with a thermometer and adjust dial assembly 

to reflect the measured temperature. 

Refer to installation sheet.

Install with new check valve (s) / stop (s).

Refer to check valves / stops removal and installation

section of the installation sheets.

Check valves / stops are not opened

all the way.

Thermostatic cartridge is damaged.

Debris in screens of thermostatic

cartridge.

Limit stops are not set properly.

Dial assembly is not calibrated.

Check valve (s) / stops are not 

opened all the way.

Install new check valves / stops.  Refer to check valves / stops

removal and installation section of the installations sheets

Remove thermostatic cartridge and clean screens.

Remove trim and make sure the arrows on the check valve / 

stops are facing toward the center of the thermostatic valve.

Check valve (s) / stops have been

damaged.

Debris in screens of thermostatic

cartridge.

Check valves / stops are not opened

all the way.

Check valve (s) / stops have been

damaged or filled with debris.

Limit stops are not set properly.

Boiler temperature not set high enough.

Install new check valves / stops.  Refer to check valves / stops

removal and installation section of the installations sheets

Refer to installation instruction for setting limit stops.

Thermostatic valve has cold water mixing with the hot water at

all times, so the water temperature on the boiler will need to 

be increased to get the desired temperature.  

CAUTION: increasing the temperature will affect all plumbing

throughout the system.  

Refer to installation sheets for proper

installation.

The shower head is trapping

water behind the faceplate.

The volume control valve has

been installed incorrectly.

The ceramic disc in the cartridge

of the volume control valve has

been damaged.

Remove shower head and clean out the holes in the faceplate.  Reinstall 

shower head.

Arrow on side of volume control should be pointing away from the 

thermostatic valve.  If arrow can not be seen, remove trim and cartridge.  

Look into the valve cavity.  The location of the larger hole indicates the 

outlet of the volume control valve, the volume control is installed incor-

rectly.  Refer to installation sheets for proper installation.

Replace with a new cartridge

TROUBLE SHOOTING GUIDE

Содержание J-TH34

Страница 1: ...NG CODES PUBLIC HEALTH AND SAFETY CODES This unit has no serviceable filter See Valve Maintenance Section RETAIN THESE DIRECTIONS FOR TRIM INSTALLATION System Requirements This thermostatic valve is d...

Страница 2: ...upply and flush valve with cartridge and check stops removed Page 9 7 Turn off water supply and re install cartridge and check stops Page 10 8 Turn on water supply and test for leaks and all functions...

Страница 3: ...stops and volume control removed Page 9 7 Turn off water supply and re install cartridge check stops and volume control Page 10 8 Turn on water supply and test for leaks and all functions 9 Twin Ell...

Страница 4: ...Figure 5 3 Remove diverter cartridge Page 6 4 Connect inlet and outlet port piping SEE PAGE 8 FOR PORTS USED BLOCKED 5 See Rough in plumbing and valve flushing Page 9 6 Turn on water supply and flush...

Страница 5: ...stops and diverter cartridge removed Page 9 7 Turn off water supply and re install thermostatic cartridge check stops and diverter cartridge Page 10 8 Turn on water supply and test for leaks and all f...

Страница 6: ...e Remove thermostatic cartridge 2 Pull outward and twist slightly to aid removal Retain for reassembly 2 CHECK STOP REMOVAL J TH34 J TH12 J TH34 686 J TH34 688 J THVC12 a Remove hot and cold check sto...

Страница 7: ...static Body Only 1 THVC12 BODY RGH 2 1 2 Thermostatic Cartridge 1 J TH12 CART 3 Thermostatic Cartridge Locknut 1 1050 3 RGH 4 Thermostatic Valve Limit Stop Ring 1 2050 4 0 5 Stainless Steel Limit Stop...

Страница 8: ...volume control is required If not port must be plugged Figure 8 3 Select diverter ports to be used C A B and plumb with appropriate fittings Part s J TH34 686 J TH34 688 J 20686 and J 20688 Note Port...

Страница 9: ...433 800 852 3906 f 908 653 1717 800 852 4133 JACLO COM PG 9 STEP 4 ROUGH IN PLUMBING AND VALVE FLUSH 1 Flush adapters are provided for placement into body for flushing THERM DIVERTER FLUSH ADAPTERS 10...

Страница 10: ...able water to the o rings on the thermostatic cartridge and insert into valve body rotating back and forth slightly Orient cartridge with the notch up in the 12 o clock position for J TH34 and and J T...

Страница 11: ...connections 6 Open diverter valve Test all positions See Figure 11 12 or 13 for diverter operation 7 Open volume control on bottom of thermostatic valve body if applicable Figure 14 8 Close hot and c...

Страница 12: ...tting from STEP 2 1b 6 Rotate thermostatic valve full counter clockwise and check water temperature with thermometer Factory setting should be 100 maximum Figure 10 7 Limit stop setup FOLLOWING STEPS...

Страница 13: ...at 12 o clock position full on C port a 9 o clock position full on B port at 3 o clock position Water volume increases as control moves toward full on positions Control moves 180 degrees through full...

Страница 14: ...ves stops removal and installation section of the installations sheets Remove thermostatic cartridge and clean screens Remove trim and make sure the arrows on the check valve stops are facing toward t...

Страница 15: ...rm to such warranty JACLO WILL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES CAUSED BY A BREACH OF THIS OR ANY OTHER WARRANTY Some states do not allow the exclusion of limitation of incide...

Страница 16: ...OCTOBER 3 2017 jaclo industries 129 Dermody Street Cranford NJ 07016 p 908 653 4433 800 852 3906 f 908 653 1717 800 852 4133 JACLO COM PG 16...

Отзывы: