INSTALLATION INSTRUCTIONS

Thermostatic Valves

Part #’s: J-TH34, J-TH12

Thermostatic Valves with Built in Diverter/Shut Off

Part #’s: J-TH34-686, J-TH34-688

Thermostatic Valve with Built in Volume Control

Part #’s: J-THVC12

Diverter Valves

Part #’s: J-20682, J-20686, J-20688

J-TH34 / J-TH12

J-THVC12

J-20682 / J-20686 / J-20688 

J-TH34-686 / J-TH34-688

FOLLOW ALL APPLICABLE LOCAL PLUMBING CODES, PUBLIC HEALTH AND SAFETY CODES

This unit has no serviceable filter.  See Valve Maintenance Section

**RETAIN THESE DIRECTIONS FOR TRIM INSTALLATION**

System Requirements

- This thermostatic valve is designed for use with pressurized hot and cold water supplies only and should not be used  

  with low-pressure storage heating systems.

- This valve was factory set to 100

°

 F maximum at a pressure of 45 PSI. The actual temperature must be checked due to  

  water temperature and pressure deviations.

Pressure: 

Recommended range 30 PSI - 70 PSI

1/2” Valve: 

1/2” NPT inlets and outlets

3/4” Valve: 

3/4” NPT inlets and outlets

Temperature: 

 

Hot water inlet - 165°F Max. - 130°F Min.

 

Marked dial range - 70°F - 120°F

 

Safety stop - Adjustable

Содержание J-TH34

Страница 1: ...NG CODES PUBLIC HEALTH AND SAFETY CODES This unit has no serviceable filter See Valve Maintenance Section RETAIN THESE DIRECTIONS FOR TRIM INSTALLATION System Requirements This thermostatic valve is d...

Страница 2: ...upply and flush valve with cartridge and check stops removed Page 9 7 Turn off water supply and re install cartridge and check stops Page 10 8 Turn on water supply and test for leaks and all functions...

Страница 3: ...stops and volume control removed Page 9 7 Turn off water supply and re install cartridge check stops and volume control Page 10 8 Turn on water supply and test for leaks and all functions 9 Twin Ell...

Страница 4: ...Figure 5 3 Remove diverter cartridge Page 6 4 Connect inlet and outlet port piping SEE PAGE 8 FOR PORTS USED BLOCKED 5 See Rough in plumbing and valve flushing Page 9 6 Turn on water supply and flush...

Страница 5: ...stops and diverter cartridge removed Page 9 7 Turn off water supply and re install thermostatic cartridge check stops and diverter cartridge Page 10 8 Turn on water supply and test for leaks and all f...

Страница 6: ...e Remove thermostatic cartridge 2 Pull outward and twist slightly to aid removal Retain for reassembly 2 CHECK STOP REMOVAL J TH34 J TH12 J TH34 686 J TH34 688 J THVC12 a Remove hot and cold check sto...

Страница 7: ...static Body Only 1 THVC12 BODY RGH 2 1 2 Thermostatic Cartridge 1 J TH12 CART 3 Thermostatic Cartridge Locknut 1 1050 3 RGH 4 Thermostatic Valve Limit Stop Ring 1 2050 4 0 5 Stainless Steel Limit Stop...

Страница 8: ...volume control is required If not port must be plugged Figure 8 3 Select diverter ports to be used C A B and plumb with appropriate fittings Part s J TH34 686 J TH34 688 J 20686 and J 20688 Note Port...

Страница 9: ...433 800 852 3906 f 908 653 1717 800 852 4133 JACLO COM PG 9 STEP 4 ROUGH IN PLUMBING AND VALVE FLUSH 1 Flush adapters are provided for placement into body for flushing THERM DIVERTER FLUSH ADAPTERS 10...

Страница 10: ...able water to the o rings on the thermostatic cartridge and insert into valve body rotating back and forth slightly Orient cartridge with the notch up in the 12 o clock position for J TH34 and and J T...

Страница 11: ...connections 6 Open diverter valve Test all positions See Figure 11 12 or 13 for diverter operation 7 Open volume control on bottom of thermostatic valve body if applicable Figure 14 8 Close hot and c...

Страница 12: ...tting from STEP 2 1b 6 Rotate thermostatic valve full counter clockwise and check water temperature with thermometer Factory setting should be 100 maximum Figure 10 7 Limit stop setup FOLLOWING STEPS...

Страница 13: ...at 12 o clock position full on C port a 9 o clock position full on B port at 3 o clock position Water volume increases as control moves toward full on positions Control moves 180 degrees through full...

Страница 14: ...ves stops removal and installation section of the installations sheets Remove thermostatic cartridge and clean screens Remove trim and make sure the arrows on the check valve stops are facing toward t...

Страница 15: ...rm to such warranty JACLO WILL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES CAUSED BY A BREACH OF THIS OR ANY OTHER WARRANTY Some states do not allow the exclusion of limitation of incide...

Страница 16: ...OCTOBER 3 2017 jaclo industries 129 Dermody Street Cranford NJ 07016 p 908 653 4433 800 852 3906 f 908 653 1717 800 852 4133 JACLO COM PG 16...

Отзывы: