BASIC FUNCTIONS

MODE SELECTION

To select a mode of operation, simply touch the

box on the screen. Based on the equipment

Mode

and thermostat configuration, mode selection can be as follows:

Off

-

Thermostat will not call for heating or cooling.

-

Thermostat will only call for heating.

Heat

-

Thermostat will only call for cooling.

Cool

-

Thermostat will call for both heating and cooling.

Auto

- Thermostat only controls emergency heat when configured for heat pump or

E.Heat

`

fossil fuel equipment.

AM

Heat

Mon

Automatic

Morning

01/01/2014

Heat Set

E

8

Содержание T-32-TS

Страница 1: ...T 32 TS Touchscreen Thermostat User Manual ...

Страница 2: ......

Страница 3: ...ooling Equipment Gas Electric 7 Heat Pump and Fossil Fuel Equipment 7 Mode Selection 8 Fan Selection 9 Programmable Fan Option 9 Changing the Heating or Cooling Temperature Setting Manual Heat Cool Mode 10 Changing the Heating or Cooling Temperature Setting Auto Mode 11 Programming 12 18 7 Day Schedule 4 or 2 Daily Events 12 13 4 Daily Events 13 17 2 Daily Events 17 Programmable Fan 18 1 ...

Страница 4: ...CONTENTS Overrides 19 20 Temporary Temperature Override 19 20 Permanent Hold 20 Other Options and Features 21 22 Adaptive Recovery Option 21 Clean Screen 21 Low Battery Indication 22 Changing the Batteries 23 2 ...

Страница 5: ...d understand this User Manual you can take advantage of the many features offered in this premium product Although great care has been taken in the preparation of this manual Jackson Systems takes no responsibility for errors or omissions contained herein It is the responsibility of the installer to ensure that this thermostat and the equipment connected to it operate in a safe and efficient manne...

Страница 6: ...CTION CAN NOT BE ACCESSED OR EXCEEDING A SET LIMIT FLASHING LOW BATTERY INDICATOR WITH AUDIBLE BEEP EVERY MINUTE UP AND DOWN ARROWS USED TO SET TEMPERATURE TIME DAY MONTH YEAR AND OTHER VALUES SPACE TEMPERATURE FAHRENHEIT ONLY MODE USED TO SELECT HEAT COOL AUTO OFF OR E HEAT ALSO DISPLAYS HEATING AND COOLING STAGES FAN USED TO SELECT AUTOMATIC OR ALWAYS ON OPERATION PROGRAM USED TO PROGRAM EVENTS ...

Страница 7: ...Heat Set During normal operation the T 32 TS typically displays the following 1 Day of the week 5 Fan selection 2 Time of day 6 Program period programmable mode only 3 Calendar M D Y 7 Mode of operation 4 Space temperature 8 Set temperature 1 2 3 4 5 6 7 8 5 ...

Страница 8: ...d then touch the clock The calendar month will flash Touch the UP or DOWN arrow to change the month then touch the clock The day of the month will flash Touch the UP or DOWN arrow to change the day of the month and then touch the clock The year will flash Touch the UP or DOWN arrow to change the year and then touch the clock After a few moments the thermostat will return to its operating mode NOTE...

Страница 9: ...NG EQUIPMENT GAS ELECTRIC Heat Cool Off Manual Changeover Heat Cool Auto Off Auto Changeover Heat Off Heat Only Cool Off Cool Only HEAT PUMP AND FOSSIL FUEL EQUIPMENT Manual Changeover Heat Cool E Heat Off Heat Cool Auto E Heat Off Auto Changeover Heat E Heat Off Heat Only Cool Off Cool Only When the thermostat is placed in the E Heat Emergency Heat mode only the auxiliary heat source is used and ...

Страница 10: ...n can be as follows Off Thermostat will not call for heating or cooling Thermostat will only call for heating Heat Thermostat will only call for cooling Cool Thermostat will call for both heating and cooling Auto Thermostat only controls emergency heat when configured for heat pump or E Heat fossil fuel equipment AM Heat Mon Automatic Morning 01 01 2014 Heat Set E 8 ...

Страница 11: ...will continue to run until it is placed in the Automatic mode PROGRAMMABLE FAN OPTION If your thermostat has been configured for Programmable Fan you can change the fan mode for each scheduled program event For example you might wish to have for the morning Always On schedule and for the Day schedule Each time the thermostat changes schedules the Automatic selected fan mode will automatically be i...

Страница 12: ... temperature setting will be displayed To change the setting simply touch the temperature displayed on the screen Depending on the mode either Heat Set or Cool Set will flash Touch the UP or DOWN arrow to change the setting The thermostat will return to its operating mode in 10 seconds and the new temperature will be displayed Heat Set E E 10 ...

Страница 13: ...creen will flash three Cool Set times and then will flash three times Heat Set To change the cooling setting touch the UP or DOWN arrow to change the setting when is Cool Set flashing To change the heating setting touch the UP or DOWN arrow to change the setting when Heat Set is flashing The thermostat will return to its operating mode in 10 seconds and the new heating and cooling temperatures wil...

Страница 14: ...ght each day of the week You can program both heating and cooling temperatures for each scheduled event when the thermostat is in the auto changeover or manual changeover mode The Auto Heat Cool thermostat can not be programmed in the mode If the thermostat is configured for heat only or Off cool only then only that mode can be programmed Simply touch select or l Mode Auto Heat Coo AM Auto Mon Aut...

Страница 15: ... TS with two programming options for 7 day scheduling You can elect to have 4 daily events or 2 daily event for Morning Day Evening Night Day Night each day of the week 4 DAILY EVENTS Press and hold Monday along with the UP and DOWN arrows will appear on the Program Mon screen Mon E 13 ...

Страница 16: ...r PM will flash Program Touch the UP or DOWN arrow to change the Morning start time hour The factory default is 6 00 AM Touch again and the minutes will flash Touch the UP or DOWN arrow to change the Program minutes which can be adjusted in 10 minute increments AM Mon Morning E 14 ...

Страница 17: ... UP or DOWN arrow to change the cooling temperature The factory default if 75 F for the morning schedule Touch again and the Morning temperature will be displayed and flash Touch the Program Heat Set UP or DOWN arrow to change the heating temperature The factory default is 70 F AM Mon Morning Cool Set E 15 ...

Страница 18: ...ar Follow the same steps The factory defaults for the Night event are 10 00 PM Cool Set 78 F Heat Set 62 F Touch again and the word copy will appear If you want to copy the Monday schedule Program cpy to consecutive days of the week touch the UP arrow to add additional days Each day that you select will flash For example you might want to copy the Monday schedule to Tuesday and Wednesday Once and ...

Страница 19: ...s The thermostat will automatically advance to the next day 2 DAILY EVENTS Seven day scheduling for 2 daily events uses the same programming steps as 4 daily events other than you only have to program and Once programming is completed the thermostat will Day Night resume normal operation in 10 seconds Mon Night E 17 ...

Страница 20: ...tomatic Always On Program to maintain fan operation for the program period Just like Temporary Automatic Temperature Override the fan mode can be changed simply by touching The program event will Fan flash confirming the Programmable Fan mode is in override To resume normal operation touch Program Hold Hold will appear Touch and the thermostat will resume programmed operation Automatic fan mode al...

Страница 21: ...affecting the programmed temperatures For example if you want to change the heating temperature simply touch the displayed temperature When flashes touch the UP Heat Set or DOWN arrows to adjust the setting The thermostat will resume normal operation in 10 seconds and display the new heating temperature The program period or Morning Day Evening Night will flash continuously to provide confirmation...

Страница 22: ...op flashing PERMANENT HOLD There may be times when a permanent override is required such as during a vacation or holiday period To place the thermostat in Permanent Hold simply touch until the word Program Hold appears Next touch the displayed temperature While or are flashing touch the Set Heat Set Cool UP or DOWN arrow to adjust the permanent hold temperature s that you want to maintain Whenever...

Страница 23: ... time Example If you program a heating temperature to be 70 degrees at 6 00 PM Adaptive Recovery will calculate when to bring the equipment on so that the temperature will be 70 degrees at 6 00 PM CLEAN SCREEN It is recommended that the touch screen be cleaned periodically Use a slightly moistened clean non abrasive cloth Touch the screen until the LCD lights up Touch the Clean Screen window All n...

Страница 24: ...me of day clock running in case of a power failure In some applications battery power is also used to control the heating and air conditioning equipment When the Low Battery icon appears on the screen change the batteries immediately AM Heat Mon Automatic Morning 01 01 2014 Heat Set LOW BATTERY ICON 22 ...

Страница 25: ...rawer out Install two AA batteries matching the Positive and Negative orientation Push the battery compartment in until it clicks shut When the batteries are properly installed the touchscreen display will resume normal operation with no loss of programming or current time AA AA 23 ...

Страница 26: ...INDIANAPOLIS IN 46203 www jacksonsystems com 06 1172 042114 ...