WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service techni-
cian. Many of the tests require that the unit have power to it and live electrical components be exposed.
USE EXTREME CAUTION WHEN TESTING THE MACHINE.
TROUBLESHOOTING SECTION
15
Possible Cause
Action
Low inlet water temperature.
Ensure incoming water is 110 F (43.33 C) at
incoming point of machine, may need to
increase the set point of the supply water
heater.
Low gas pressure.
Check gas supply pressure.
Ensure proper operation of combination gas
cutoff valve.
Ensure manual gas cutoff valve is open.
Check gas supply pressure.
Check for kinks in flexible gas supply line.
Improper circulation through system.
Check recirculating pump operation. Check
for obstructions.
T-set needs adjustment.
Ensure set point is approximately 4.25 VDC.
Defective T-mid thermistor (Red LED light
may be flashing).
Check Ohms reading is between 950 and
1150 Ohms when probe is at room
temperature. Check for frayed wiring.
Ensure connection to control board.
Defective control board (ECB).
Perform auto-calibration. Ensure power
supplied to board is +12 VDC. Ensure green
LED light is flashing.
T-set needs adjustment.
Ensure set point is approximately 4.25 VDC.
ECO failure. (Overprotection feature is
faulty and does not open at 210 F) (98.89
C).
Remove wire from ECO terminal. If burner
unit turns off, ECO may be defective.
Replace ECO.
Symptom
Low rinse temperature/low wash
temperature.
High rinse temperature.
Содержание Gas Heated Door-Type Dishmachines Tempstar...
Страница 31: ...INCOMING PLUMBING ASSEMBLY 29 11 12 13 15 16 10 09 08 07 17 18 19 20 06 05 04 03 02 01 26 25 24 23 22 21 14...
Страница 36: ...STEAM COIL ASSEMBLY 34 01 02 03 05 06 07 08 10 11 12 13 14 15 16 04 09 17 18...
Страница 41: ...Tempstar TGP ELECTRICAL DIAGRAM 208 240 VOLT 50 HERTZ 1 PHASE 39...