![Jackson Delta 5 D Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/jackson/delta-5-d/delta-5-d_installation-operation-and-technical-manual_628789008.webp)
Delta 5 Installation & Operation Manual 7610-003-37-08
Issued: 05-25-2007 Revised: 03-08-2013
SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS OF THE DELTA 5
2
F
OPERATING CAPACITY ( NSF RATED):
RACKS PER HOUR
29
DISHES PER HOUR
725
GLASSES PER HOUR
725
OPERATING CYCLES (SECONDS):
NORMAL CYCLE:
WASH TIME
45
RINSE TIME
25
TOTAL CYCLE TIME
90
WASH TANK CAPACITY (GALLONS):
1.2
WASH PUMP CAPACITY (GPM):
61
OPERATING TEMPERATURES:
WASH (MINIMUM)
(48.9°C) 120°F
WASH (RECOMMENDED)
(60.0°C) 140°F
RINSE (MINIMUM)
(48.9°C) 120°F
RINSE (RECOMMENDED)
(60.0°C) 140°F
WATER REQUIREMENTS:
WATER LINE SIZE NPT
1/2”
DRAIN LINE SIZE NPT
2”
FLOW PRESSURE
20
5 PSI
MINIMUM CHLORINE REQUIRED (PPM):
50
ELECTRICAL REQUIREMENTS:
WASH PUMP MOTOR HP
3/4
RINSE
TYPICAL
HEATER
TOTAL ELECTRICAL
VOLTS
PH
HZ
RATINGS
AMPS
CIRCUIT
115
1 60 2KW@110V *16 A
20 AMP
* This dishmachine is designed so that the wash motor is never
running when the wash heater is on. Service load is based upon
the higher of the two amperages.
NOTE: Typical Electrical Circuit is based upon (1) 125% of the
full amperage load of the machine and (2) typical fixed-trip
circuit breaker sizes as listed in the NEC 2002 Edition. Local
codes may require more stringent protection than what is
displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets
all applicable national and local codes. These numbers are
provided in this manual simply for reference and may change
without notice at any given time.
FRAME DIMENSIONS:
WIDTH
(622.3mm)
24 1/2”
DEPTH
(641.35mm)
25 1/4”
DEPTH, WITH FRONT DOOR OPEN (933.45mm)
36 3/4”
HEIGHT
(990.6mm) 39”
MAXIMUM WASH
CHAMBER CLEARANCE
(292.1mm) 11 1/2”
FRAME DIMENSION (DOUBLE DOOR):
WIDTH (622.3MM) 24 1/2”
DEPTH (714.375MM) 28 1/8”
DEPTH, WITH DOOR OPEN (1311.275MM) 51 5/8”
HEIGHT
(990.6MM) 39”
CHAMBER CLEARANCE (292.1MM) 11 1/2”
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to change
without notice.
Содержание Delta 5 D
Страница 7: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Страница 10: ...4 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Страница 18: ...12 SECTION 3 PREVENTATIVE MAINTENANCE ...
Страница 20: ...14 SECTION 4 TROUBLESHOOTING ...
Страница 23: ...17 SECTION 5 PARTS SECTION ...
Страница 43: ...37 SECTION 6 ELECTRICAL SCHEMATICS ...
Страница 45: ...39 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...
Страница 52: ......