![Jackson CREW 44 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/jackson/crew-44/crew-44_installation-operation-and-service-manual_628849035.webp)
26
07610-003-78-18-N
ITEM
QTY
DESCRIPTION
PART NUMBER
PLC1
1
PLC, 24VDC (Programmed for 44" Units)
(Programmed for 44" Units with Blower/Dryer)
05945-003-92-50
05945-004-10-84
T1
1
Transformer 208 to 120VAC (208V Units)
Transformer 230/460 to 120VAC
05950-011-75-59
05950-011-68-35
T2
1
Power Supply 24VDC
05950-003-76-32
PLC 1 & 2
1
(Programmed for 66" Units)
06401-004-13-59
PLC 1 & 2
1
(Programmed for 66" Units with Blower/Dryer)
06401-004-13-61
12
10
11
10
C3
TB1
C2
C1
TB2
PLC2
PLC1
T2
T1
8
9
1
HC1
TB3
TB4
3
2
3
4
6
5
7
1MOL
3MOL
2MOL
R1
R2
R3
R4
R5
R6
13
TB5
All operational relays use green LED-indicating lights
to verify proper operation. These relays are mounted
immediately to the right of the motor contactors.
Please refer to the illustration at right.
R1
R2
R3
R4
R5
LED
The illustration above depicts the components of a 66" electrically-heated unit with the booster heater option.
Component quantities and part numbers might vary for different units. Please refer to the notes within the parts list
on the next page to verify that the required part number is correct.
CONTROL BOX COMPONENTS
PARTS
Содержание CREW 44
Страница 2: ......
Страница 6: ......
Страница 81: ...72 07610 003 78 18 N STEAM BOOSTER HEATER SCHEMATICS ...
Страница 84: ...75 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 ELECTRICALLY HEATED SCHEMATICS ...
Страница 85: ...76 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 ELECTRICALLY HEATED SCHEMATICS ...
Страница 86: ...77 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 44 STEAM HEATED SCHEMATICS ...
Страница 87: ...78 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 44 STEAM HEATED SCHEMATICS ...
Страница 88: ...79 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 ELECTRICALLY HEATED SCHEMATICS ...
Страница 89: ...80 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 ELECTRICALLY HEATED SCHEMATICS ...
Страница 90: ...81 07610 003 78 18 N 208 230 460 VOLT 60 HZ 3 PHASE 66 STEAM HEATED SCHEMATICS ...
Страница 91: ...82 07610 003 78 18 N 208 230 VOLT 60 HZ 1 PHASE 66 STEAM HEATED SCHEMATICS ...
Страница 92: ...83 07610 003 78 18 N BLOWER DRYER 240V SCHEMATICS ...
Страница 93: ...84 07610 003 78 18 N BLOWER DRYER 480V SCHEMATICS ...