07610-003-92-84-T
6
Model Designation:
XL-E/XL-E-FL
XL-E-LTH
XL HH
Operating Capacity:
Racks per Hour
39
39
39
Dishes per Hour
975
975
975
Glasses per Hour
1404
1404
1404
Tank Capacity (Gallons):
Wash Tank 1.02 (40.2 GPH) 1.02 (40.2 GPH)
1.61 (62.8 GPH)
Electrical Loads (as applicable):
Wash
Motor
HP
1
1
1
Operating Times (seconds):
Normal Medium Heavy
Wash
42 42 100 280
43
Rinse
25 25 25 25
25
Dwell
20 20 20 20
18
Water Temperatures (°F):
Minimum Wash Temperature
120
120
120
Recommended Wash Temperature
N/A
140
N/A
Minimum Rinse Temperature
120
120 120
Recommended Rinse Temperature
N/A
145
N/A
Minimum Incoming Water Temperature
120
110 120
Other Water Requirements:
Water Flow Pressure (PSI)
20 +/- 5
20 +/- 5
20 +/- 5
Flow Rate Minimum (GPM)
6.18
6.18
9.66
Water Line Size (NPT)
3/4”
3/4”
3/4”
Drain Line Size (NPT)
2”
2”
2”
Minimum Chlorine Required (PPM)
50
50
50
Always refer to the machine data plate for specific electrical and water requirements.
The material provided on this page is for reference only and is subject to change without notice.
OPERATING CAPACITIES
SPECIFICATIONS
NOTICE
Содержание CONSERVER XL HH
Страница 51: ...07610 003 92 84 T 43 XL E FL DOOR PARTS SECTION A A A A 6 5 1 2 16 10 9 11 4 7 13 15 3 12 17 14 8 ...
Страница 61: ...07610 003 92 84 T 53 XL E LTH BOOSTER TANK PARTS 16 ...
Страница 65: ...07610 003 92 84 T 57 SCHEMATICS XL E XL HH 115 V 60 HZ 1 PHASE ...
Страница 66: ...07610 003 92 84 T 58 SCHEMATICS XL E XL HH 208 V 60 HZ 1 PHASE ...
Страница 67: ...07610 003 92 84 T 59 SCHEMATICS XL E LTH 208 230 V 60 HZ 1 3 PHASE ...
Страница 68: ...07610 003 92 84 T 60 SCHEMATICS XL E FL 115 V 60 HZ 1 PHASE ...
Страница 69: ......