1
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY
(RACKS/HOUR)
RACKS PER HOUR
24
DISHES PER HOUR
600
GLASSES PER HOUR
600
OPERATING CYCLE
(SECONDS)
WASH TIME
56
DRAIN TIME
29
RINSE TIME
35
TOTAL CYCLE TIME
120
TOTAL WATER CONSUMPTION
GALLONS PER HOUR (80% CAP.)
28.8
GALLONS PER RACK
1.2
TEMPERATURES
WASH ---°F (MINIMUM)
120
WASH ---°F (RECOMMENDED)
140
RINSE ---°F (MINIMUM)
120
RINSE ---°F (RECOMMENDED)
140
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER
3/4
NOTE: Typical Electrical Circuit is based upon (1) 125% of the
full amperage load of the machine and (2) typical fixed-trip
circuit breaker sizes as listed in the NEC 2002 Edition. Local
codes may require more stringent protection than what is
displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets
all applicable national and local codes. These numbers are
provided in this manual simply for reference and may change
without notice at any given time.
RINSE
TYPICAL
HEATER
TOTAL ELECTRICAL
VOLTS PH
HZ
RATINGS
AMPS
CIRCUIT
115 1 60
N/A
10
15 AMP
WATER REQUIREMENTS
INLET TEMPERATURE (RECOMMENDED)
140°F
INLET TEMPERATURE (MINIMUM)
120°F
GALLONS PER HOUR
28.8
WATER LINE SIZE NPT (MINIMUM)
1/2”
DRAIN LINE SIZE NPT (MINIMUM)
1 3/8”
FLOW PRESSURE P.S.I.
20
A
5
MINIMUM CHLORINE REQUIRED (PPM)
50
FRAME DIMENSIONS
WIDTH
24 1/4”
DEPTH
22 5/8”
HEIGHT
33 1/4”
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to change
without notice.
SPECIFICATIONS
Содержание CONSERVER 24LT
Страница 2: ......
Страница 38: ...35 CONSERVER 24LT ELECTRICAL DIAGRAM 115 VOLT 60 HERTZ SINGLE PHASE 05700 031 74 04 ...
Страница 39: ...36 CONSERVER 24LTP ELECTRICAL DIAGRAM 115 VOLT 60 HERTZ SINGLE PHASE ...
Страница 40: ...IMPORTANT INFORMATION DATA SHEET 37 Model Serial No Installation Date Service Rep Name Phone No Notes ...