NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These numbers are provided in this manual simply for reference
and may change without notice at any given time.
RINSE TYPICAL
HEATER TOTAL
ELECTRICAL
MODEL
VOLTS
PH HZ
RATINGS
AMPS
CIRCUIT
AJ-44TE
208
1 60 N/A
97 A
125 AMP
AJ-44TE
230
1 60 N/A
89 A
125 AMP
AJ-44TE
208
3 60 N/A
57 A
80 AMP
AJ-44TE
230
3 60 N/A
49 A
70 AMP
AJ-44TE
460
3 60 N/A
25 A
35 AMP
AJ-44TG
208
1 60 N/A
12 A
15 AMP
AJ-44TG
230
1 60 N/A
12 A
15 AMP
AJ-44TG
208
3 60 N/A
8 A
15 AMP
AJ-44TG
230
3 60 N/A
8 A
15 AMP
AJ-44TG
460
3 60 N/A
5 A
15 AMP
AJ-44TS
208
1 60 N/A
11 A
15 AMP
AJ-44TS
230
1 60 N/A
11 A
15 AMP
AJ-44TS
208
3 60 N/A
7 A
15 AMP
AJ-44TS
230
3 60 N/A
7 A
15 AMP
AJ-44TS
460
3 60 N/A
4 A
15 AMP
AJ-66TE
208
1 60 N/A
103 A
150 AMP
AJ-66TE
230
1 60 N/A
95 A
125 AMP
AJ-66TE
208
3 60 N/A
61 A
80 AMP
AJ-66TE
230
3 60 N/A
52 A
70 AMP
AJ-66TE
460
3 60 N/A
26 A
35 AMP
AJ-66TG
208
1 60 N/A
18 A
25 AMP
AJ-66TG
230
1 60 N/A
18 A
25 AMP
AJ-66TG
208
3 60 N/A
12 A
15 AMP
AJ-66TG
230
3 60 N/A
12 A
15 AMP
AJ-66TG
460
3 60 N/A
7 A
15 AMP
AJ-66TS
208
1 60 N/A
17 A
25 AMP
AJ-66TS
230
1 60 N/A
17 A
25 AMP
AJ-66TS
208
3 60 N/A
11 A
15 AMP
AJ-66TS
230
3 60 N/A
11 A
15 AMP
AJ-66TS
460
3 60 N/A
6 A
15 AMP
AJ-80TE
208
1 60 N/A
106 A
150 AMP
AJ-80TE
230
1 60 N/A
97 A
125 AMP
AJ-80TE
208
3 60 N/A
63 A
80 AMP
AJ-80TE
230
3 60 N/A
58 A
80 AMP
AJ-80TE
460
3 60 N/A
29 A
40 AMP
AJ-80TG
208
1 60 N/A
19 A
25 AMP
AJ-80TG
230
1 60 N/A
19 A
25 AMP
AJ-80TG
208
3 60 N/A
13 A
20 AMP
AJ-80TG
230
3 60 N/A
13 A
20 AMP
AJ-80TG
460
3 60 N/A
7 A
15 AMP
AJ-80TS
208
1 60 N/A
19 A
25 AMP
AJ-80TS
230
1 60 N/A
19 A
25 AMP
AJ-80TS
208
3 60 N/A
13 A
20 AMP
AJ-80TS
230
3 60 N/A
13 A
20 AMP
AJ-80TS
460
3 60 N/A
7 A
15 AMP
AJ-44T Series Technical Manual 7610-003-07-21
Issued: 03-21-2006 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
3
Содержание AJ-44TE
Страница 9: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Страница 33: ...25 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Страница 44: ...36 SECTION 3 PREVENTATIVE MAINTENANCE ...
Страница 48: ...40 SECTION 4 TROUBLESHOOTING SECTION ...