background image

Zone Control Made Simple™

5418 Elmwood Avenue, Indianapolis, IN 46203-6025
Toll Free: 888.652.9663 Fax: 317.227.1034
www.jacksonsystems.com

Specifications

Panel Dimensions:

8.0 Inches

Height:

6.0 Inches

Width:

1.375 Inches

Depth:

Mounting:

Snap Track with 2 back plate screws

Operating Temperature Rating:

-40° F to 150° F

Operating Humidity:

5% to 90% RH non-condensing

Wiring:

18-gauge wire for all equipment

and system connections

Time Delays:

3 minutes minimum off between
heating and cooling calls
3 minutes minimum off on high and low
limit
20 minute time share

Thermostats:

Single or multi-stage heat pump
Programmable or non-programmable
Auto or manual changeover

Dampers:

D PC

Powered Closed

D C

Common

PO

Powered Open

High / Low Limit

DAS

Discharge Air Sensor
(2 wire)

Outdoor Thermostat

OTS

Used for Fossil Fuel
(2 wire)

HVAC Equipment:

RH

24Vac Heating Transformer

RC

24Vac Cooling Transformer

W

Auxiliary Heat

Y1

First Stage Compressor

Y2

Second Stage Compressor

G

Fan

O/B

Reversing Valve

Panel Power:

R

24Vac (Hot)

X

24Vac (Common)

Terminal Designations

Thermostats:

C

24Vac (Common)

R

24Vac (Hot)

W

Auxiliary Heat

Y1

First Stage Compressor

Y2

Second Stage
Compressor

G

Fan

06-1054-011510

ZONE DAMPER 3

ZONE DAMPER 1

ZONE 1

STAT

ZONE 3

STAT

Z-300

PANEL

24 VOLT

TRANSFORMER

FURNACE

DISCHARGE AIR

SENSOR

ZONE 2

STAT

ZONE DAMPER 2

Z-300-HPS Installation and Operation Instructions

3 Heat / 2 Cool Heat Pump or Dual Fuel

Auto Changeover - First Call Priority - Time Share

Z NE

N

E

E

R

G

E

H

T

Zone Control Made Simple

TM

TM

Typical System Layout

Purge ON = 1 minute

Отзывы: