background image

Zone Control Made Simple™

5418 Elmwood Avenue, Indianapolis, IN 46203-6025
Toll Free: 888.652.9663 Fax: 317.227.1034
www.jacksonsystems.com

Specifications:

Panel Dimensions:

Mounting:

Operating Temperature Rating:

Operating Humidity:

Wiring:

Time Delays:

Thermostats:

Height:

8.0 Inches

Width:

6.0 Inches

Depth:

1.375 Inches

Snap Track with 2 back plate screws

-40° F to 150° F

5% to 90% RH non-condensing

18-gauge wire for all equipment

and system connections

3 minutes minimum off between
cooling calls
3 minutes minimum off on low limit
20 minute time share

Single-stage heat / cool thermostats
Programmable or non-programmable
Auto or manual changeover

Z NE

N

E

E

R

G

E

H

T

Zone Control Made Simple

TM

TM

Dampers:

High / Low Limit

HVAC Equipment:

Panel Power:

D

Powered Closed / Spring Open

D

(2 wire)

DAS Discharge Air Sensor
DAS (2 wire)

R

24Vac (Hot)

W1

First Stage Heat

W2

Second Stage Heat

Y1

First Stage Cool

Y2

Second Stage Cool

G

Fan

X

24Vac (Common)

H

24Vac (Hot)

Typical System Layout

ZONE DAMPER 2

MIGHT SERVE

BEDROOM AREA

ZONE DAMPER 1

MIGHT SERVE

LIVING AREA

ZONE 1

STAT

ZONE 2

STAT

Z-200-HC-MS

PANEL

24 VOLT 40VA

TRANSFORMER

FURNACE

HIGH/LOW

LIMIT

SENSOR

Terminal Designations:

Thermostats:

C

24Vac (Common)

R

24Vac (Hot)

W1

First Stage Heat

W2 Second Stage Heat
Y1

First Stage Cool

Y2

Second Stage Cool

G

Fan

Z-200-HC-MS Installation and Operation Instructions

2 Heat / 2 Cool - Auto Changeover - First Call Priority - Time Share

06-1035-072011