PERFORMANCE/CAPABILITIES
OPERATING CAPACITY
(RACKS/HOUR)
SELECTION (A)
RACKS PER HOUR
53
DISHES PER HOUR
1325
GLASSES PER HOUR
1325
SELECTION (B)
RACKS PER HOUR
29
DISHES PER HOUR
725
GLASSES PER HOUR
725
SELECTION (C)
RACKS PER HOUR
20
DISHES PER HOUR
500
GLASSES PER HOUR
500
SELECTION (D)
RACKS PER HOUR
12
DISHES PER HOUR
300
GLASSES PER HOUR
300
OPERATING CYCLE
(SECONDS)
SELECTION (A)
WASH TIME
45
RINSE TIME
15
TOTAL CYCLE TIME
60
SELECTION (B)
WASH TIME
103
RINSE TIME
15
DWELL TIME
2
TOTAL CYCLE TIME
120
SELECTION (C)
WASH TIME
163
RINSE TIME
15
DWELL TIME
2
TOTAL CYCLE TIME
180
SELECTION (D)
WASH TIME
283
RINSE TIME
15
DWELL TIME
2
TOTAL CYCLE TIME
300
TANK CAPACITY
RINSE TANK (GALLONS)
3
WASH TANK (GALLONS)
8
WASH PUMP CAPACITY
GALLONS PER MINUTE
73
FRAME DIMENSIONS
WIDTH
25 3/4”
DEPTH
25 1/4”
HEIGHT
68 1/2”
STANDARD TABLE HEIGHT
34”
MAXIMUM INSIDE CLEARANCE
27”
RACKS
DISH 20” X 20”
OPTIONAL
GLASS & SILVER 20” X 20”
OPTIONAL
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HP
2.0
FULL LOAD AMPS (12 KW BOOSTER HEATER)
VOLTS
PHASE
AMPS
208 1
74.2
230 1
80.9
208 3
47.6
230 3
51.0
460 3
23.4
FULL LOAD AMPS (14 KW BOOSTER HEATER)
VOLTS
PHASE
AMPS
208 1
50.5
230 1
56.1
208 3
29.1
230 3
32.4
460 3
25.8
FULL LOAD AMPS (NO BOOSTER HEATER)
VOLTS
PHASE
AMPS
208 1
30.9
230 1
33.0
208 3
22.6
230 3
23.8
460 3
9.6
WATER REQUIREMENTS
INLET WATER TEMPERATURE (12 KW)
140°F
INLET WATER TEMPERATURE (14 KW)
110°F
INLET WATER TEMPERATURE (NO BOOSTER
HEATER)
180°F
WASH TEMPERATURE (MINIMUM)
150°F
RINSE TEMPERATURE (MINIMUM)
180°F
GALLONS PER RACK
1.36
WATER LINE SIZE I.P.S. (MINIMUM)
3/4”
DRAIN LINE SIZE I.P.S. (MINIMUM)
1-1/2”
FLOW PRESSURE P.S.I. (OPTIMUM)
20
SPECIFICA
TIONS OF THE TEMPST
AR HH & TEMPST
AR HH NB
1
Содержание TEMPSTAR HH
Страница 10: ...MAIN ASSEMBLY 8 1 3 4 2 5 6 2 7 8 11 10 12 9 Represents an item not shown...
Страница 19: ...CANTILEVER ARM ASSEMBLY 17 1 2 3 4 5 6 9 10 7 8 18 19 18 21 20 17 14 16 12 15 13 11 12 14 22...
Страница 32: ...30 Tempstar HH ELECTRICAL DIAGRAM 208 230 Volt 60 Hertz Single Three Phase...
Страница 33: ...Tempstar HH ELECTRICAL DIAGRAM 460 Volt 60 Hertz Three Phase 31...
Страница 35: ...Tempstar HH NB ELECTRICAL DIAGRAM 460 Volt 60 Hertz Three Phase 33...