Micro-JLT GNSS™ User Manual
36
© 2019 Jackson Labs Technologies, Inc.
Figure 3.4 PTIMe:STAMp:FILT DUR Timing Example
3.5.16 PTIMe:STAMp:FILTer:PPSecond <int> [1,100]
The PTIMe:STAMp:FILTer:PPSecond command is unrelated to OCXO disciplining. For more infor-
mation on OCXO disciplining, please refer to Section
.
This command specifies the maximum number of time-stamps that can be stored over any one sec-
ond interval. However, this command will not be effective if the PTIMe:STAMp:FILT PPS filter
described in Section
is disabled. If this command is sent, then the pulse storage period speci-
fied in the PTIMe:STAMp:FILTer:1PPeriod command in Section
maximum number of pulses stored per second is 100 pulses.
The following command will query the state of the PTIMe:STAMp:FILTer:PPSecond command:
PTIMe:STAMp:FILTer:PPSecond?
Below is an example of the results displayed for the PTIMe:STAMp:FILTer:PPSecond 1 command.
A timing diagram for this example can be found in
.
GPS time-stamp: 2060, 174275.000000025 (This time-stamp is stored)
EXT time-stamp: 2060, 174275.000000560 (This time-stamp is filtered out with the
PTIMe:STAMp:FILTer:PPSecond 1 command)
Содержание Micro-JLT GNSS
Страница 1: ...Micro JLT GNSS User Manual Document 80200550 Version 1 2 Date November 6 2019...
Страница 2: ...Micro JLT GNSS User Manual Copyright 2019 Jackson Labs Technologies Inc...
Страница 10: ...Micro JLT GNSS User Manual 4 2019 Jackson Labs Technologies Inc...
Страница 68: ...Micro JLT GNSS User Manual 62 2019 Jackson Labs Technologies Inc...
Страница 78: ...Micro JLT GNSS User Manual 72 2019 Jackson Labs Technologies Inc...