background image

10 

 

S

TORAGE

 

When  the  appliance  is  not  in  use  the  LP  cylinder  must  be 
disconnected.  Store  your  campfire  in  a  dry  place.  This 
appliance may be stored indoors but the LP cylinder must be 

stored  outdoors  in  a  well-ventilated  area  out  of  reach  or 
children.  
If the Patio Fire is to be transported or stored, the hose and 

regulator  assembly  must  be  wrapped  around  the  center  of 
the  base.  Do  not  wrap  so  tight  as  to  kink  the  hose  at  the 
base connection end. Hook one end of the supplied bungee 

cord  onto  the  hand  wheel  of  the  regulator  (see  Figure  14) 
making  sure  the  end  of  the  POL  nipple  points  inward  (for 

protection).  Stretch  the  other  end  of  the  bungee  around  to 
where the hose attaches to the base and hook on as shown 
in Figure 15. 
Disconnected  cylinders  must  have  threaded  valve  plugs 
tightly installed and must not be stored in a building, garage 
or any other enclosed area. 
Enclosures for LP-gas supply cylinders shall be ventilated by 
openings at the level of the cylinder valve and at floor level. 
The  effectiveness  of  the  opening(s)  for  the  purposes  of 

ventilation  shall  be  determined  with  the  LP-gas  supply 
cylinder(s) in place. This shall be accomplished by one of the 
following: 

a) One side of the enclosure shall be completely open; or 
b) For an enclosure having four (4) side, a top and a bottom: 

1. At least two (2) ventilation openings at cylinder valve level shall be provided in the side 

wall, equally sized, spaced at 180 degrees (3.14 rad), and unobstructed. Each opening 
shall have a total free area of not less than 1⁄2 square inch per pound (3.2 sq. cm/kg) 
of stored fuel capacity and not less than a total free area of 10 square inches (64.5 sq. 

cm). 

2. Ventilation opening(s) shall be provided at floor level and shall have a total free area of 

not less than 1⁄2 square inch per pound (3.2 sq. cm/kg) of stored fuel capacity and not 

less than a total free area of 10 square inches (64.5 sq. cm). If ventilation openings at 
floor level are in a sidewall, there shall be at least two (2) openings. The bottom of the 
openings shall be at floor level and the upper edge no more than 5 inches (127 mm) 

above the floor. The openings shall be equally sized, spaced at 180 degrees (3.14 rad), 
and unobstructed. 

3. Every opening shall have minimum dimensions so as to permit the entrance or a 1⁄8 

inch (3.2 mm) diameter rod. 

The cylinder’s valve shall be readily accessible for hand operation. A door on the enclosure to gain 
access to the cylinder valves is acceptable, provided it is non-locking and can be opened without 

the use of tools. 
There shall be a minimum clearance of 2 inches (50.8 mm) between the lower surface of the floor 
of the LP-gas supply cylinder enclosure and the ground. 

Figure 14

 

 

Figure 15

 

 

Содержание Patio Fire

Страница 1: ...WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switches do not use the phone in your building Immediately call your gas supplier from a neighbor s phone Foll...

Страница 2: ...ety Precautions 3 Specifications 4 Assembly 4 Campfire Placement 4 Lighting Instructions 5 Turning Off Gas To Campfire 6 Log Ember Placement 6 Natural Gas Conversion 8 Care Maintenance 9 Storage 10 Wa...

Страница 3: ...temperatures and should stay away to avoid burn or clothing ignition Young children should be carefully supervised when they are in the area of the appliance FOR YOUR SAFETY Installation and service m...

Страница 4: ...essure regulator provided with this appliance must be used This regulator is set for an outlet pressure of 11 inch W C 2 74 kPa The LP gas supply cylinder s to be used with this campfire must be arran...

Страница 5: ...Re open the LP cylinder valve if bubbles start to form between the valve and the hose there is still a leak see your dealer If no bubbles are seen continue to c c Open the gas line valve if bubbles s...

Страница 6: ...in their existing holes Figure 4 shows the Jackson Grills Patio Fire burner clean and empty The burner ports and alignment pins are highlighted for reference When placing the logs ensure that they do...

Страница 7: ...7 Figures 7 through 10 Place logs 3 to 6 using the images below Figure 9 Figure 10 Figure 7 Figure 8 Place the ember fibers over the burner making sure to cover all the burner slots...

Страница 8: ...er loosen the screw on the air shutter located on the burner turn the shutter so that it is completely closed Re tighten the screw Re install burner in reverse order 6 Using a 18 mm wrench remove prop...

Страница 9: ...the campfire body To clean the burner wait until the campfire has completely cooled Gently remove the log set and embers CAREFULLY LIFT each log STRAIGHT UP off of the center tube and alignment pins s...

Страница 10: ...or an enclosure having four 4 side a top and a bottom 1 At least two 2 ventilation openings at cylinder valve level shall be provided in the side wall equally sized spaced at 180 degrees 3 14 rad and...

Страница 11: ...ers defects in materials and workmanship only if the product has been installed and used according to the manual s instructions If the product is damaged or broken as a result of misuse or mishandling...

Страница 12: ...Part Number Part Description TPR18THA Tee Handle Assembly TPR18LID Lid TPR18WG Wind guard TPR18LS Log set TPR18EMB Embers 2 bags TPR18LPB LP Burner TPR18BDY Body TPR18HRA Hose Regulator Assembly TPR1...

Отзывы: