9
Cut Out (Framing) Dimensions:
A.
Installing in an outdoor cabinet:
This grill must be safely and correctly installed as a built in, before being used. Please refer to the chart below, for
correct installation dimensions.
Framing must enclose the grill on the back and sides, but the bottom of the cut-out may be left open. The grill is
supported by the three flanges (left, right and rear), so no support underneath is required. NOTE: please ensure that
fuel line openings provide adequate space for the lines.
CABINET FRAMING DIMENSIONS:
*NOTE: Rear cabinet back splash (if applicable) and counter top must be non-combustible.
Clearance to Combustibles:
A)
TOP:
Minimum clearance from grill surface to combustible construction*
Do not use this appliance
under overhead combustible
surfaces.
*Such as decks, ceilings, hanging plants, etc.
B)
REAR:
from rear of unit to any combustibles behind grill:
12”/30.48 cm minimum
C)
SIDE:
from the outside edges the grill body, to any adjacent combustibles:
15 ½”/39.37 cm minimum
Built In Grill Cutout Dimensions
Cabinets with Non-Combustible Materials
(Eg: metal studs, cement board, tiles, marble)
MODEL
A
Width
B*
Depth
C*
Height
D*
E*
F*
Supreme
JSS 550 Bi
24 ¾”
18 ¾”
10”
5 ½”
12”
15 ½”
Metric (cm)
62.87
47.63
25.4
13.97 30.48 39.37
Supreme
JSS 700 Bi
33”
18 ½”
10 ¼”
5 ½”
12”
15 ½”
Metric (cm)
83.82
47
26.04
13.97 30.48 39.37
Supreme
JSS 850 Bi
40”
18 ½”
10 ¼”
5 ½”
12”
15 ½”
Metric (cm)
101.6
47
26.04
13.97 30.48 39.37
*B
Depth is measured from the finished face of the
island/cabinet. Notching of countertop front may be
required.
*C
Height is measured from the finished countertop
down.
*D
Minimum distance to rear vertical wall; required to
fully open lid (from cutout).
*E/F
Minimum distance to rear/side adjacent vertical
combustibles
E
A
F
D
C
B
!WARNING!
Please allow extra space when the grill is backed up to vinyl siding;
exhaust exiting the rear of the grill can warp or melt the vinyl.
Содержание JSS850BI-LP
Страница 22: ...22 Exploded View JSS Built In...