Factory Reset
(Err-01)
REASON:
Hardware overcurrent
The way to check:
1.
2.
Replace the control box with “Replace exclusion method” to see whether the control box is
damage or not.
3.
Replace the main shaft motor with “Replace exclusion method” to see whether the motor is
damage.
Solution:
1.
If the power supply voltage is not in the normal range, please check the power cable design
is normal or not.
2.
If the control box is damage, please replace it or send it back to supplier for repairing.
3.
If the motor is damaged, please replace it or send it back to supplier for repairing.
Check whether the power supply voltage is 220V +/-20V with a multimeter;
(
-06)
Err
REASON:
Solenoid circuit fault
The way to check:
1.
check the DC resistance of each solenoid is normal or not with a multimeter (you can
compare with the normal machine)
2.
Replace the control box with “Replace exclusion method” to see whether the control box is
damage or not.
Solution:
1.
If any of the solenoid is damage, please replace that solenoid.
2.
If the control box is damage, please replace it or send it back to supplier for repairing.
The way to check:
1.
check if power line connection between motor and control box is broken or not.
2.
Interchange the control box to check it it is the control box problem.
Solution:
1.
If connection problem, just need to improve connection.
2.
If control box problem, change another one or send the defective control box back to
company to repair.
(Err-07)
REASON:
Current sensor fault
Common fault treatment(1)
Common fault treatment(2)
Common fault treatment(3)