Model 37055 • Forms 43000-0663
UP
12 Vdc
10
25
#16 (1,5 mm
2
)
#14 (2,5 mm
2
)
#12 (4 mm
2
)
#10 (6 mm
2
)
#8 (10 mm
2
)
24 Vdc
5
15
#16 (1,5 mm
2
)
#16 (1,5 mm
2
)
#16 (1,5 mm
2
)
#14 (2,5 mm
2
)
#12 (4 mm
2
)
*
Length of run is total distance from power source to product and back to ground.
ELECTRICAL SPECIFICATIONS
VOLTAGE DRAW
SIZE
0'-10' (0 M-3 M)
10'-15' (3 M-4,6 M)
15'-25' (4,6 M-7,6 M)
25'-40' (7,6 M-12,2 M )
40'-60'(12,2 M-18,3 M)
The electrical wiring should be independent of all
other accessories. It should be made with marine
grade copper stranded wire of the gauge specified
in the electrical specifications chart. Make all
wire connections with mechanical locking type
connectors (crimp type butt connectors and
terminals). Ensure the circuit is protected by a
proper sized fuse or circuit breaker determined
from the electrical specifications chart. Secure all
wires to a solid surface approximately every
eighteen inches (1/2 M) along their entire length
of run.
Wire the switch panel to the solenoid valve/siphon
breaker and toilet pump assembly as per the
following wiring diagram. Connect the brown lead
from the panel to the waste pump positive (orange)
lead. Connect the black waste pump motor lead to
battery negative. Connect the yellow lead from
the panel to a solenoid valve terminal. Connect
the remaining solenoid valve terminal to battery
negative. Select a location for the switch panel
that is convenient to the toilet user and will also
INSTALLATION -
ELECTRICAL
Page 3
allow access to run the wires from the switch
panel to both the toilet’s motor and the solenoid
valve/siphon breaker as well as from the electrical
power source to the switch panel. To install the
switch panel, drill two 1-3/4" (45 mm) diameter
holes (slightly over-lapping) through the selected
switch mounting surface per the attached tem-
plate. Ensure the template is oriented correctly
because it is not symmetrical. Also, drill four
appropriate sized holes for the fasteners selected
to secure the switch panel to its mounting surface.
YELLOW
RED
To
Positive
To Solenoid
Valve/Siphon
Breaker
BROWN
To Waste Pump
Positive
(Orange)
Motor Lead
BROWN
YELLOW
RED
YELLOW
BROWN
RED
RED
WIRING DIAGRAM
1-3/4" (45 mm) DIA
1-3/4" (45 mm) DIA
TEMPLATE