3.5 Home arming 

 

The installer can program particular detectors so that they will be automatically 

bypassed in the so called “Home” partial arming. This allows for people to stay in 

the particular part of the house after arming. To arm partially:    

 

On the keypad 

press home arming button  

 

H

 will indicate the Home partial arming on the keypad. 

 

To disarm a partially armed system 

-

 

enter your user code or press the   or    

button on the remote control. 

 

3.6 Door opening 

 

An electrical door lock (if installed) can be controlled via the alarm system. 

  Press the 

door opening button 

on the keypad to release the 

lock.  

 

3.7 Alarm memory reading 

 

All events (arming, disarming, alarms, failures…) are recorded into the control 

panel’s memory along with the time and date. The complete system history can be 

viewed using a PC with Comlink software. Alarms and failures can also be viewed 

on the keypad by entering: 

 

F 4 

- will show the last recorded alarm or failure. Press key 4 multiple 

times to go deeper in to the memory.  

 

3.8 Split system arming 

 

The system can be split by the installer into two independent sections (A,B) and 

a shared section (corridors, stairs, a main door…). This allows for a particular user 

to arm and disarm only a particular section of the house with his/her code or 

remote control (exactly as in a non split system). Arming of sections A and B is 

indicated by 

I I

  symbols on the keypad. The shared section will be armed 

automatically when A and B sections are both armed.  

  

With the master code the supervisor can arm and disarm both sections. If the 

master code is entered, the system will arm (if completely disarmed) or disarm (if 

any section is armed).  

Entering 

F1 master code

 will control only section 

A

 and 

F2 master code

 only 

section 

(this is true only when fast arming is disabled by the installer). 

Note: 

partial Home arming is not possible if the system is split.

 

Alarm system JA-63 „Profi“ 

- 7 - 

MGK51504 

Содержание Profi

Страница 1: ...JA 63 Profi User manual...

Страница 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Страница 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Страница 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Страница 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Страница 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Страница 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Страница 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Страница 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Страница 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Страница 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Страница 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Страница 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Страница 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Страница 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Страница 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Отзывы: