jablotron Profi Скачать руководство пользователя страница 12

Example:

 to store tel. number 0 123456 to memory no. 2 enter: 

7 0 F0 12345 F2

 

 

To delete a telephone number 

enter:    

7 F0 F

y

 

 

where 

y

 

is a memory number from 1 to 4 

 

 

To 

exit user mode,

 press the 

key. 

 

 

5.2.2  Telephone communicator testing 

 

Testing is possible in the user mode. To switch the control panel to the user 

mode enter 

F 0 master code

. User mode will be indicated by a 

U

 on the keypad.   

 

Entering 

89

 will cause the communicator to send voice message number 2 to all 

programmed telephone numbers. It will also send an SMS message if 

programmed. The telephone line signals will be audible from the control panel’s 

built in speaker during the test (if the dialer is triggered by an alarm in normal 

operation, it will call silently). Testing can be terminated with the 

N

 key. 

 

 

 

Notify the people 

who will be called before testing! 

 

To 

exit user mode,

 press the 

key. 

 

6  System testing 

 

 The supervisor should test the system monthly. For testing the control panel 

should be in the user mode. Enter 

F0 master code

 to switch to the user mode (

U

 

will be indicated on the keypad).  

  No alarm can be triggered while in the user mode and any triggering of a 

detector, a remote control or a panic button will be indicated on the keypad.  

 

Note: 

some detectors (for example the wireless motion detector) in normal mode can not 

send the next triggering information until 5 minutes after the previous triggering was sent. It 

is possible to switch such a detector to the testing mode by opening and closing its cover. 

See the particular product manual for more details.  

 

If anything does not work during testing, call the installer.  

 

To 

exit user mode

 press 

N

 

 

7  Battery replacement  

 

All the battery-powered items perform regular battery testing. If the lifetime of the 

battery is near the end, the system will indicate the need for battery replacement 

(Battery indicator and the item address will be shown on the keypad).  

  When any detector or keypad asks for new batteries, they should be replaced in 

a week. To replace batteries either call the installer or do the following: 

  switch the control panel to the user mode (entering 

F0 master code

)  

Alarm system JA-63 „Profi“ 

- 12 - 

MGK51504 

Содержание Profi

Страница 1: ...JA 63 Profi User manual...

Страница 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Страница 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Страница 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Страница 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Страница 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Страница 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Страница 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Страница 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Страница 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Страница 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Страница 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Страница 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Страница 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Страница 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Страница 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Отзывы: