JA-63 „PROFI“ Alarm System
- 16 -
MGK55401
13 Recommended professional in-
staller basic rules
If you install the system for a customer, you should follow
these rules:
•
make a drawing of intended location of the items,
keeping in mind proper protection for the intended
area.
•
if the customer requests reduction of the system (price
reasons etc.), ask for a written confirmation that he
does not want the particular items you recommended
(to avoid blame and liability if poorly covered area is
robed in the future)
•
make a professional installation and do not forget to
clean and be tidy.
•
it is very important to explain to the customer all
functions of the system, to teach to him or her how to
program access codes, how to test the system and
how to replace batteries in the items
•
offer your regular assistance for testing and battery
replacement (we recommend annually)
•
make a written report signed by the customer, that the
installation was finished properly and that she or he
received your training on how to operate and test the
system
14 Trouble shooting table
Problem possible
cause
solution
alarm after first powering
the control panel is not in factory default setting
perform a factory default reset
connected JA-60E keypad has no
function
connecting cable does not connect the corresponding positions in the
keypad and in the control panel (1-1, 2-2, 3-3, 4-4)
Check the colors of the cores in the cable
and positions on each side
impossible to enroll a wireless item
location of the item is not suitable and the radio signal level is too low
(too far away or an obstacle is in the way of communication)
change location of the item, (fix it in the
new place temporary at first and then try it)
a fault is indicated on the keypad
and it is beeping
check display for the reason of the trouble. Press key N to disable
beeping. The trouble information is stored in the event memory and it
can be reviewed entering F4 anytime in the future
check the reason of the trouble in user
manual and fix it, or call the installer
If JA-65X is used, telephone line
failure is indicated and the phone
works as normal
when you make a phone call longer than 15 minutes, it is interpreted
by the system that the tel. line is not ready.
if this problem repeats, disable tel. line
checking in programming mode
PIR movement detector repeatedly
triggers alarms with no visible
reason
check if there are: animals in the protected area (mice...), sudden
changes of temperature or intense air circulation, movement of
objects with temperature of about 37°C etc.
increase detector’s immunity (internal
setting), change location of the detector or
use an optional sensor’s lens
fault or alarm C is indicated
blown fuse in the control panel or radio communication jamming
PC with Comlink SW gives details
when activated, the tel. dialer calls
a number multiple times
the telephone network does not use standard recognition signals and
the dialer is not sure if the connection was successful or not
store F0 after the last digit of the
problematic number
system does not communicate
with connected PC
the PC-60A cable is not connected to the correct COM connector on
the PC
check the connection or select the port
number in SW manually
problem is not in this list
call installer or the distributor for advice
local hot line number:
15 Possibilities to extend the system
15.1 Extension of the system with a subsystem
An additional JA-6x control panel can be enrolled as a
subsystem to the control panel (see 9.11.). Each system then
can be operated either as an independent system, or the main
control panel can arm and disarm the sub-control panel. Any
event in the subsystem (alarm, tampering, failure or low battery)
will trigger the same kind of event on the main control panel (the
main control panel will display "J" as the event source). The
main control panel will not indicate the number of the item which
triggered the event, but this information is available on the
subsystem’s control panel.
Using this method, multiple level subsystems can be chained.
Warning: never enroll the top level control panel as a
subsystem of the lower level control panel. This would create
endless circle for the data and such an alarm system chain
would not work properly.
15.2 Extension of the system with a communicator
GSM communicator JA-60GSM
By using GSM communicator JA-60GSM you will get supervision
over the system wherever you are. Communicator sends SMS
messages, calls to predefined telephone numbers and plays
audible warning, communicates with 2 CMS, allows remote access
from a phone’s keypad and can be set and operate via web page
www.GSMlink.cz.
Digital communicator JA-65X
Communicator JA-65X can communicate with a Monitoring
Station, send two voice messages, send five SMS messages
via SMS server (if it is supported in your country or dial a
numeric Pager). It can also communicate with a remote PC
(using ComLink SW and a JA-60U modem). By remotely
connected PC it is possible to set and/or operate the control
panel.
15.3 Brief overview of parts suitable for the JA-63
system
The brief overview you got along with this manual includes the
basic assortment of accessories. Jablotron is systematically
introducing new and improved items to the market. You can get
the most current information from your distributor or you can visit
Jablotron’s Internet home page at: www.jablotron.com