JA-63 „PROFI“ Alarm System 

- 16 - 

MGK55401 

 

 

13 Recommended  professional  in-

staller basic rules 

  

If you install the system for a customer, you should follow 

these rules: 

• 

make a drawing of intended location of the items, 
keeping in mind proper protection for the  intended 
area. 

• 

if the customer requests reduction of the system (price 
reasons etc.), ask for a written confirmation that he 
does not want the particular items you recommended 
(to avoid blame and liability if poorly covered area is 
robed in the future) 

• 

make a professional installation and do not forget to 
clean and be tidy. 

• 

it is very important to explain to the customer all 
functions of the system, to teach to him or her how to 
program access codes, how to test the system and 
how to replace batteries in the items 

• 

offer your regular assistance for testing and battery 
replacement (we recommend annually) 

• 

make a written report signed by the customer, that the 
installation was finished properly and that she or he 
received  your training on how to operate and test the 
system 

 

 

 

14  Trouble shooting table 

 

Problem possible 

cause 

solution 

alarm after first powering  

the control panel is not in factory default setting  

perform a factory default reset 

connected JA-60E keypad has no 
function 

connecting cable does not connect the corresponding positions in the 
keypad and in the control panel (1-1, 2-2, 3-3, 4-4)  

Check the colors of the cores in the cable 
and positions on each side 

impossible to enroll a wireless item 
 

location of the item is not suitable and the radio signal level is too low 
(too far away or  an obstacle is in the way of communication) 

change location of the item, (fix it in the 
new place temporary at first and then try it) 

a fault is indicated on the keypad 
and it is beeping 

check display for the reason of the trouble. Press key N to disable 
beeping. The trouble information is stored in the event memory and it 
can be reviewed entering F4 anytime in the future 

check the reason of the trouble in user 
manual and fix it, or call the installer  

If JA-65X is used, telephone line 
failure is indicated and the phone 
works as normal 

when you make a phone call longer than 15 minutes, it is interpreted 
by the system that the tel. line is not ready. 

if this problem repeats, disable tel. line 
checking in programming mode 

PIR movement detector repeatedly 
triggers alarms with no visible 
reason  

check if there are: animals in the protected area (mice...), sudden 
changes of temperature or intense air circulation, movement of 
objects with temperature of about 37°C etc.   

increase detector’s immunity (internal 
setting), change location of the detector or 
use an optional sensor’s lens  

fault or alarm C is indicated  

blown fuse in the control panel or radio communication jamming  

PC with Comlink SW gives details 

when activated, the tel. dialer calls 
a number multiple times 

the telephone network does not use standard recognition signals and 
the dialer is not sure if the connection was successful or not 

store F0 after the last digit of the 
problematic number  

system does not communicate 
with connected PC 

the PC-60A cable is not connected to the correct COM connector on 
the PC 

check the connection or select the  port 
number in SW manually 

problem is not in this list 

call installer or the distributor for advice  

local hot line number: 

 

 

15  Possibilities to extend the system 

 
 

15.1  Extension of the system with a subsystem 

  

An additional JA-6x control panel can be enrolled as a 

subsystem to the control panel (see 9.11.). Each system then 
can be operated either as an independent system, or the main 
control panel can arm and disarm the sub-control panel. Any 
event in the subsystem (alarm, tampering, failure or low battery) 
will trigger the same kind of event on the main control panel (the 
main control panel will display "J" as the event source). The 
main control panel will not indicate the number of the item which 
triggered the event, but this information is available on the 
subsystem’s control panel. 

 Using this method, multiple level subsystems can be chained. 

 

Warning: never enroll the top level control panel as a 

subsystem of the lower level control panel. This would create 
endless circle for the data and such an alarm system chain 
would not work properly. 

 

15.2  Extension of the system with a communicator 

 

GSM communicator JA-60GSM 

By using GSM communicator JA-60GSM you will get supervision 
over the system wherever you are. Communicator sends SMS 
messages, calls to predefined telephone numbers and plays 
audible warning, communicates with 2 CMS, allows remote access 
from a phone’s keypad and can be set and operate via web page 
www.GSMlink.cz.

 

 
Digital communicator JA-65X 

Communicator JA-65X can communicate with a Monitoring 
Station, send  two voice messages, send five SMS messages 
via SMS server (if it is supported in your country or dial a 
numeric Pager). It can also communicate with a remote  PC 
(using ComLink SW and a JA-60U modem). By remotely 
connected PC it is possible to set and/or operate the control 
panel.

 

 

15.3  Brief overview of parts suitable for the JA-63 

system  

The brief overview you got along with this manual includes the 

basic assortment of accessories. Jablotron is systematically 
introducing new and improved  items to the market. You can get 
the most current information from your distributor or you can visit 
Jablotron’s Internet home page at: www.jablotron.com 

 

Содержание JA-63 PROFI"

Страница 1: ...JA 63 PROFI Alarm system installation manual...

Страница 2: ......

Страница 3: ...ication 12 9 19 Arming and disarming chirps with wired siren 12 9 20 Siren alarm in Disarm Partial arming 12 9 21 Wireless siren alarm 12 9 22 Indication of system problems when arming 12 9 23 Control...

Страница 4: ...ssages calls to predefined telephone numbers and plays audible warning communicates with 2 CMS allows remote access from a phone s keypad and can be set via web page Operation and programming is possi...

Страница 5: ...nd used to hang it from the wall Its active part from the plastic ring to the coil should be installed vertically and should not be obstructed by any large metal object The antenna can be located behi...

Страница 6: ...e setting in the programming mode see 9 6 The control panel also wirelessly transmits the PGX and PGY signals and UC receiving units can be used as remote outputs for these signals U is a back up powe...

Страница 7: ...ess item manual when installing After you install the item to the desired location leave it un powered and without its cover The method of enrollment is described in section 9 1 7 Back up battery inst...

Страница 8: ...YES 310 NO YES Siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabled 33x 331 YES 330 NO YES Partial arming exit delay audible indication 34x 341 YES 340 NO NO Entrance dela...

Страница 9: ...ill enroll to position A when its power is switched on If you need to enroll a siren which is already powered and it is not possible to easily switch off its power you can enroll it the following way...

Страница 10: ...ed message and phone number editing in the user mode sequence 2 5 x The User mode which is accessible with F 0 Master Code is for bypass setting system testing and battery replacement This setting ena...

Страница 11: ...etter understanding you can simply imagine that the master control panel is just another remote control Arming control of the subsystem by the master control panel can be disabled by erasing the corre...

Страница 12: ...setting has no effect options 3 7 1 alarm in disarm partial arming enabled 3 7 0 alarm in disarm partial arming disabled Factory default setting enabled 9 21 Wireless siren alarm sequence 3 8 x The w...

Страница 13: ...e triggered or a fault indication will be generated when communication with the detectors is lost and the control panel is armed Options 6 9 6 1 Communication loss causes an alarm 6 9 6 0 Communicatio...

Страница 14: ...completed Time Setting 4 hh mm dd MM YY where hh hours 24 hr cycle mm minutes dd day MM month YY year Example on Jun 30 2007 at 17 15 enter 4 17 15 30 06 07 After the control panel is powered its inte...

Страница 15: ...C 60A interface cable Comlink software is designed for the Windows system User can check and operate the JA 63 system easily via their PC can read complete events memory with all details can view the...

Страница 16: ...change location of the detector or use an optional sensor s lens fault or alarm C is indicated blown fuse in the control panel or radio communication jamming PC with Comlink SW gives details when acti...

Страница 17: ...uts Alarm relay dry contacts 1A 60V programmable outputs PgX PgY Chime Fire Arm Panic Alarm Door Home AC failure siren output 12 V 0 7 A Wireless outputs control panel transmits signals for siren and...

Отзывы: